26/06/2007  Page 2 

Installation 

 

 

Install only on an external wall, as close as possible to the most frequently used hot 

tap. Use a heat shield (accessory item part number 9 708 061 400) if the unit is to be installed 

on a combustible surface. Allow minimum air gap of 10 mm between the flue and the heat 

shield, (refer figure 2). 

 

Ensure that the flue terminal is clear of any combustible material, and avoid 

installation in a marine environment. 

 

Install the appliance such that the base of the appliance is not more than 1.3 metres 

and not less than 0.5 meters from the ground, and allow for easy access to service heater. 

 

Secure heater to wall using two 10g X 5/16 hex head wood screws 

(Ramset 610041 or similar)

Locate head of screw in the key hole of the top mounting bracket. 

Fig. 2 

 

Pipe Connections

   

Refer to Fig. 1 for locations 

 

Hot and Cold water ½" male  

Natural gas ¾" female 

L.P. gas ½" male 

 

 

A gas cock must be installed in the gas supply line with provision to disconnect the 

appliance. Install gate valve or full flow ball valve (fixed mechanism type) in cold water supply. 

A non return valve must not be fitted. Example duo valve 

 

 

We recommend that all hot water pipes be lagged if the runs are long or exposed, and 

water-proof lagging should be used on all external hot water pipes. If the water supply 

pressure exceeds 80% of the specified maximum, install a pressure limiting valve. 

If installing a pressure limiting valve fit a cold expansion valve between the limiting valve and 

the appliance.    PLV = 500kPa   Cold expansion = 700kPa 

 

Refer to AG 601 and AS3500.1 for the relevant pipe size. 

 

NOTE:

Service calls for incorrect pipe sizing will 

NOT

 be covered under warranty. 

 

Water Filter 

 

 

If sludge or foreign matter is or may be present in the water supply, it is recommended 

that a suitable filter be incorporated in the water supply line to the heater. All pipes should be 

well flushed before connection is made. 

A water filter/strainer is installed in the inlet of the brass water valve inside the appliance. 

 

Water Temperature Adjustment 

 

 

Located inside the water heater, immediately below the gas controls, is a water 

temperature selector knob. 

To increase the water temperature ( decrease water flow ) turn the knob clockwise. To reduce 

water temperature ( increase water flow ) turn the knob anti clockwise. 

Summary of Contents for Water Wizard 600

Page 1: ...d only by an authorised person This appliance is not suitable for use as a pool heater The authorised installing person is responsible for 1 Correct commissioning of this appliance 2 Ensure unit performs to the specifications stated on the rating label 3 Demonstrate operation of unit to customer before leaving 4 Hand these instructions to customer Failure to install this appliance in accordance wi...

Page 2: ...m type in cold water supply A non return valve must not be fitted Example duo valve We recommend that all hot water pipes be lagged if the runs are long or exposed and water proof lagging should be used on all external hot water pipes If the water supply pressure exceeds 80 of the specified maximum install a pressure limiting valve If installing a pressure limiting valve fit a cold expansion valve...

Page 3: ...ight hand corner of the back panel for additional data Freezing Weather In areas where the atmospheric temperature may drop below 0 C the heater must be drained to prevent damage by expansion of freezing water For appliances installed in locations where the temperature falls below 0 C for brief periods the installation of an EXOGEL expansion valve part number H 707 060 151 will minimise the possib...

Page 4: ...rate as indicated in Fig 3 Refit front cover and tighten screws Fig 3 Warning If the pilot light is extinguished wait 5 minutes before attempting to relight the appliance If the appliance does not operate burns with yellow flame leaks water or a gas smell is evident turn off and contact the local gas authority the manufacturer or an authorised service person When attempting to light the appliance ...

Page 5: ...nt left hand side of burner manifold refer Fig 5 Pos A attach manometer turn on hot water tap fully and check pressure Adjust pressure by turning the knurled wheel clockwise to increase gas pressure anti clockwise to decrease refer Fig 4 Pos E LP Gas Pressure Adjustment No adjustment is provided at the appliance for inlet pressure check cylinder regulator and pipe sizing Adjust burner pressure sam...

Page 6: ... and pipe size Check appliance regulator Check thermostat bellows Check thermostat insert Low water temperature Water flow rate set too high Low gas pressure Thermostat faulty out of adjustment Set flow rate Check pressure Replace Adjust thermostat Low water flow Low water pressure Blocked water valve Blocked heat exchanger Blocked shower rose or tap aerator Check and adjust Clean filter Descale C...

Page 7: ...placement or repair at the option of RBAU of any defective products and of such parts of RBAU s products as have been damaged in consequence of the defect despite proper treatment Parts replaced will not be returned c I Repairs and maintenance shall not extend the warranty period of the appliance ii If the product is located outside of the service agent s area the consumer shall be responsible for...

Reviews: