Page 32 of 85
Fault
Possible cause
Troubleshooting
Gasket leaking
Drum lighting leaking
Gasket leaking due to friction on lighting
► Install lamp retainer [ 00631842] up to FD9310.
► Replace gasket
Appliance won't switch on/off
Main switch jammed
Main switch on electronics jams
Manufacturing period FD 9401
-FD 9409
► Control module (OU) must be replaced.
► Control panel and jog dial
must not
be replaced.
Foreign objects under the drum.
► Remove foreign objects
Foreign objects in the pump.
► Remove foreign objects
Blockage in the pump sump
► Remove blockage from the pump sump.
Drainage hose kinked
► Install drainage hose without kinks.
Blockage in the water outlet
► Check drainage hose for blockage.
► Siphon blocked
Pump off
No or inadequate draining.
Water level sensor defective
► Replace water level sensor.