WARNING

1. Flammable  materials,  gasoline,  pressurized  containers,

or  any  other  items  or  articles  that  are  potentially  fire
hazards  must  never  be  placed  on  or  adjacent    to  the
heater.  The  appliance  area  must  be  kept  free  of  all
combustible  materials,  gasoline  and  other  flammable
vapors and liquids.

2. Do not obstruct the flow of combustion and ventilation

air to the appliance.

CLEARANCES

This  heather  is  designed  certified  for  installation  on  a
combustible wall, in an alcove with minimum clearances to
combustible  construction  of  51mm  (2  inches)  from  sides,
305mm  (12  inches)  from  top  and  bottom.  A  minimum  of
305mm  (12  inches)  shall  be  allowed  for  maintenance  of
serviceable parts. Clearance from vent is dependent upon
the  clearance  rating  of  the  venting  material  used;  that  is
type B-1 vent is approved for 1 inch clearance, B-2 vent for
2 inch, etc.

MOUNTING

The W125K…is designed certified for mounting to a wall.
The  heather  must  not  be  installed  directly  on  a  carpeted
wall.

The heather must be mounted to the wall using appropriate
anchoring materials, through the four holes provided.

Expansion and contraction of piping due to changing water
temperature in pipes imparts movement to heater which, if
mounted  directly  to  a  brittle,  board  such  as  plasterboard
can cause failure of mounting.

Heater must be mounted level to assure proper operation.

VENTING

The  BOSCH  model  W125K…  instantaneous  gas  water
heater has a built-in a draft diverter is designed for indoor
installation only. The draft diverter outlet must be connected
to a clear, unobstructed vent of the same size or larger, refer
to:
-

In Canada, CAN 1-B149 Installation Code for detailed
requirements

-

In U.S., ANZI Z223.I/NFPA 54 National Fuel Gas Code
for detailed requirements

-

The minimum length of a vertical vent up to the terminal
must be 2 ½ feet.

WATER CONNECTIONS

The W125K comes supplied with a ½’’ NPT cold water inlet
adapter and a flexible wire braid hot water outlet with a ½’’
NPT connection.

Figure 2

RELIEF VALVE

The listed pressure relief valve supplied must be installed
near  the  hot  water  outlet  at  time  of  installation  of  the
heater. No valve is to be placed between the relief valve
and the heater. A drain line must be connected to the
relief valve to direct discharge to a safe location. Do not
install reducing coupling or any other restriction in the
discharge line. The discharge line must be installed so
as to allow complete
drainage of both the valve and the line.

GAS CONNECTIONS

Before  connecting  the  gas  supply  to  the  heater  check
heater’s model/rating plate to make sure that gas on which
heater is to operate is the same as specified on the model/
rating plate.

The W125K…instantaneous gas water heater is supplied
with a gas pipe, a gas pressure regulator and a manual gas
cock that must be installed on the heater before attaching
the gas supply line, see figure 3. Failure to install gas pipe,
the  main  manual  gas  valve  and  the  pressure  regulator,  or
the failure to install them in the sequence show in figure 3
will be in violation of the A.G.A. and C.G.A. certification of
the unit and can cause damage to heat changer.

BOSCH  water  heaters  are  shipped  from  the  factory  with
the gas pressure regulators preset for the gas shown on the
rating plate to the correct pressure.
-

In Canada, for high altitude operation;

-

In U.S., for standard altitude operation unless specially
marked as a high altitude unit.

G

7

7

2_1

7

9

Summary of Contents for W 125 T1

Page 1: ...TO INSTALLER Please leave this manual with the owner or affix adjacent to appliance Instantaneous gas water heater WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other applicance WHAT TO DO IF YOU SMELL...

Page 2: ...nds for high altitude installations above 2 000 feet that the input rate be reduced 4 for each 1 000 feet above sea level DIMENSIONS Figure 1 Standard High Standard High 5 7 4 6 10 5 8 4 3 35 2 7 10 2 8 1 LPG Altitude Tap pressure inch Manifold burner pressure inch Altitude Tap pressure inch Manifold burner pressure inch NG A B C D E F G H J M 270 610 230 190 70 562 350 312 102 138 10 5 8 25 3 8 9...

Page 3: ...ocated in an area where leakage of the heater or its connections will not result in damage to the area adjacent to the heater or to lower floors of the structure Note When such locations can not be avoided it is recommended that a suitable drain pan adequately drained be installed under the heater The pan must not restrict combustion air flow AIR REQUIREMENTS For safe operation sufficient air for ...

Page 4: ... Canada CAN 1 B149 Installation Code for detailed requirements In U S ANZI Z223 I NFPA 54 National Fuel Gas Code for detailed requirements The minimum length of a vertical vent up to the terminal must be 2 feet WATER CONNECTIONS The W125K comes supplied with a NPT cold water inlet adapter and a flexible wire braid hot water outlet with a NPT connection Figure 2 RELIEF VALVE The listed pressure rel...

Page 5: ...k for gas leakage Soap and water solution or other material acceptable for this purpose shall be used in locating gas leaks Matches candles lighters or other ignition sources shall not be used for this purpose WARNING The heater and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess 3 45 KPa psi...

Page 6: ...ead the safety information first section of the Lighting Instruction Plate on the cover 2 The main manual gas valve must be closed turn valve handle clockwise see fig below and the gas valve button slide to the far left under the OFF mark 3 Wait five 5 minutes to clear out any gas If you smell gas stop Follow B in the safety information above on this label If you don t smell gas go to next step 4 ...

Page 7: ...e right Turn counter clockwise more water Warm The control knob regulates the water temperature by ad justing the flow rate of the water through the heater Maximum flow rate through the heater is 5L min 1 3 U S gal min with temperature rise of 25 C 45 F at full input Minimum flow rate through the heater is 2 3 L min 0 6 U S gal min with temperature rise of 55 C 99 F at full input For normal hot wa...

Page 8: ...3 Wash in soap and water and then rinse 4 Reassemble Check for gas leaks after reassembly and correct as required 5 Refer to Lighting Procedure to relight the heater VENTING The vent piping and finned heat exchanger should be checked at least once a year for dust and carbon deposits and cleaned as necessary PRESSURERELIEF VALVE At least once a year the pressure relief valve should be checked to in...

Page 9: ...OT WATER OUTLET HAS BEEN UPGRADED TO A FLEXIBLE TUBE NOTE POSITIOON OF ASSEMBLY FLAT COPPER WASHER INSIDE BUSHING THEN ATTACHED TO MALE END OF FLEX TUBE DO NOT OVER TIGHTEN 8 703 305 197 8 700 203 027 8 700 703 038 ...

Page 10: ...10 ...

Page 11: ...11 Pilot burner 75 8708105538 11a Filter 8700507055 12 Pilot injector 5 NG 8708200005 12 Pilot orifice 49 LPG 8748200173 13 Pilot gas pipe 8700707334 14 Thermocouple 8747202083 15 Gas valve NG 8707011466 15 Gas valve LPG 8707011145 16 Magnetic unit 8707201012 17 Termo connection 8747202209 18 Water valve 8707002497 19 Repair set for water valve cover 8703406204 20 Diaphragm 8700503050 21 Slow igni...

Page 12: ...ASTRAVAN DISTRIBUTORS LTD 123 Charles Street North Vancouver B C V7H 1S1 Phone Canada 604 929 5488 Phone USA 206 860 8448 Web Site www astravan com ...

Page 13: ...e eau instantané à gaz AVERTISSEMENT Si les instructions de ce manuel ne sont pas scrupuleusement observées il pourra exister un risque d incendie ou d explosion susceptible de provoquer des dommages matériels et ou des blessures graves ou mortelles Ne pas remiser ou utiliser de l essence ou un autre produit inflammable liquide ou gazeux au voisinage de cet appareil ou de tout autre appareil ménag...

Page 14: ... thermique de 4 pour chaque palier de 1000 pieds au delà de 2000 pieds au dessus du niveau de la mer DIMENSIONS Figure 1 RACCORDEMENT GAZ RACCORDEMENT EAU SORTIE D EAU OBSTRUÉE A B C D E F G H J M 270 610 230 190 70 562 350 312 102 138 10 5 8 25 3 8 9 1 8 7 1 2 2 3 4 22 1 8 13 3 4 12 1 4 4 5 3 8 Standard Haute Standard Haute Pression de connexion po 5 7 4 6 Pression de connexion po 10 5 8 4 Pressi...

Page 15: ...ne éventuelle fuite d eau ne fera pas subir de dommages aux locaux adjacents ou des étages inférieurs du bâtiment Note Si l emplacement d installation ne peut satisfaire ces critères on recommande d installer sur le chauffe eau un plateau de récupération adéquatement relié à une canalisation d évacuation Le plateau utilisé ne doit pas entraver la circulation d air de combustion DEMANDE D AIR Une q...

Page 16: ...uation doit être raccordée à un conduit d évacuation sans obstruction de même taille ou plus grand voir la plus récente édition des normes suivantes Norme CAN1 CGA B149 Code d installation des appareils à combustion de gaz pour le Canada Norme ANSI Z223 1 National Fuel Gas Code pour les É U La longueur minimale d un conduit d évacuation vertical jusqu au point de décharge est de 2 5 pi RACCORDEMEN...

Page 17: ...tification des fuites utiliser une solution de savon et eau ou un autre produit acceptable à cette fin Ne jamais utiliser allumette bougie briquet ou autre source de flamme pour rechercher les fuites AVERTISSEMENT À l occasion de tout test de pressurisation de la tuyauterie de gaz à une pression supérieure à 3 45 kPa 1 2 lb po rel on doit déconnecter le chauffe eau et son robinet d arrêt individue...

Page 18: ...Le robinet d arrêt manuel principal de la canalisation de gaz doit être fermé rotation du bouton dans le sens horaire voir la figure ci dessous pousser également le bouton du robinet de gaz au maximum vers la gauche sous la marque ARRÊT 3 Attendre cinq 5 minutes l évacuation de tout résidu de gaz Si une odeur de gaz est perceptible arrêter Observer les instructions de sécurité B présentées ci dess...

Page 19: ...sélection fait varier la température de l eau par contrôle du débit d eau à travers le chauffe eau Le débit maximum de circulation de l eau à travers le chauffe eau est de 5 L min ceci correspond à une augmentation de température de 25 C 45 F pour le débit thermique maximum Le débit minimum de circulation de l eau à travers le chauffe eau est de 2 3 L min ceci correspond à une augmentation de temp...

Page 20: ...fuites après le remontage veiller à éliminer toute fuite 5 Pour allumer de nouveau le chauffe eau voir la section Allumage ÉVACUATION DES GAZ DE COMBUSTION Inspecter l échangeur de chaleur et la canalisation d évacuation à intervalles de douze mois ou moins rechercher les dépôts de poussière et carbone effectuer tout nettoyage nécessaire SOUPAPE DE SÉCURITÉ À intervalle de un an ou moins inspecter...

Page 21: ...E EST UTILISÉ POUR LA SORTIE D EAU CHAUDE NOTER LA CONFIGURATION D ASSEMBLAGE RONDELLE PLATE DE CUIVRE À L INTÉRIEUR DU RACCORD INSTALLÉ À L EXTRÉMITÉ MÂLE DU CONDUIT FLEXIBLE NE PAS SERRER EXCESSIVEMENT 8 703 305 197 8 700 203 027 8 700 703 038 ...

Page 22: ...10 ...

Page 23: ...ge 8708107002 11 Veilleuse 8708105538 11a Filtre 8700507055 12 Injecteur de veilleuse 5 GN 8708200005 12 Injecteur de veilleuse 49 PROP 8748200173 13 Tube veilleuse 8710707166 14 Thermoélément Sécurité veilleuse 8747202083 15 Bloc gaz GN 8707011466 15 Bloc gaz PROP 8707011145 16 Tête magnétique 8707201012 17 Thermocâbles 8747202209 18 Valve eau 8707002497 19 Couvercle d étanchétité 8703406204 20 M...

Page 24: ...ASTRAVAN DISTRIBUTORS LTD 123 Charles Street North Vancouver C B V7H 1S1 Téléphone Canada 604 929 5488 Téléphone É U 206 860 8448 Site Internet www astravan com ...

Reviews: