background image

2

en | Important Safety Instructions

Fiber Optic Media Converter

F.01U.134.924 | 1.0 | 2009.09

Installation Guide

Bosch Security Systems, Inc.

You can view and print the full version of this Installation 

Manual with Adobe Acrobat Reader. This user guide is the 

intellectual property of Bosch Security Systems; protected by 

copyright.

WARNING! 

High risk: This symbol indicates an imminently hazardous 

situation such as “Dangerous Voltage” inside the product.

If not avoided, this will result in an electrical shock, serious 

bodily injury, or death.

!

CAUTION! 

Medium risk: Indicates a potentially hazardous situation.

If not avoided, this could result in minor or moderate bodily 

injury.

!

CAUTION! 

Low risk: Indicates a potentially hazardous situation.

if not avoided, this could result in property damage or risk of 

damage to the unit.

Summary of Contents for VG4-SFPSCKT

Page 1: ...VG4 Fiber Optic Media Con verter VG4 SFPSCKT en Installation Guide ...

Page 2: ......

Page 3: ...tallation Guide F 01U 134 924 1 0 2009 09 Table of Contents 1 Important Safety Instructions 1 1 1 Customer Support and Service 3 2 Installing the Fiber Optic Module 5 2 1 Description 5 2 2 Using an SFP Module 6 2 3 Parts Included 7 2 4 Installation Instructions 8 3 Troubleshooting 13 ...

Page 4: ...iv en Table of Contents Fiber Optic Media Converter F 01U 134 924 1 0 2009 09 Installation Guide Bosch Security Systems Inc ...

Page 5: ...nit 5 Unplug the unit during lightning storms or when unused for long periods 6 Adjust only those controls specified in the operating instructions 7 Do not overload outlets and extension cords as this can cause fire or electrical shock 8 Protect the plug and power cord from foot traffic or pinching at electrical outlets and at its exit from the unit 9 Operate the unit only from the type of power s...

Page 6: ...protected by copyright WARNING High risk This symbol indicates an imminently hazardous situation such as Dangerous Voltage inside the product If not avoided this will result in an electrical shock serious bodily injury or death CAUTION Medium risk Indicates a potentially hazardous situation If not avoided this could result in minor or moderate bodily injury CAUTION Low risk Indicates a potentially...

Page 7: ... com Customer Service Telephone 888 289 0096 Fax 585 223 9180 E mail security sales us bosch com Technical Support Telephone 800 326 1450 Fax 585 223 3508 or 717 735 6560 E mail technical support us bosch com Canada Telephone 514 738 2434 Fax 514 738 8480 Europe Middle East Africa Region Repair Center Telephone 31 0 76 5721500 Fax 31 0 76 5721413 E mail RMADesk STService nl bosch com Asia Region R...

Page 8: ...erter F 01U 134 924 1 0 2009 09 Installation Guide Bosch Security Systems Inc Warranty and more information For additional information and warranty queries please contact your Bosch Security Systems representative or visit our website at www boschsecurity com ...

Page 9: ...ting the Ethernet TCP IP Communications Module This media converter module is designed to accept any of the 10 100 Mbps Small Form factor Pluggable SFP modules described below The media converter module along with the SFP module is user installed directly into the AutoDome s power supply box to provide an integrated fiber optic solution The Fiber Optic module accepts the following SFP modules Sub ...

Page 10: ...ne in the VG4 SFPSCKT module then you must use the other in the CNFE2MC head end unit For example SFP 25 is used in the VG4 SFPSCKT module installed into a VG4 power supply You must use the SFP 26 module in the CNFE2MC head end unit The following chart lists the compatibility between the SFP modules SFP Sub module used in VG4 SFPSCKT Use this SFP Sub module in CNFE2MC SFP 2 SFP 2 SFP 3 SFP 3 SFP 2...

Page 11: ...1 0 2009 09 2 3 Parts Included Part Description Part Number Fiber Optic Media Converter Module F 01U 136 512 Metal adaptor base plate F 01U 072 866 Power harness black F 01U 026 085 Four 4 Plastic standoff pins F 01U 073 233 Ethernet patch cable blue with RJ45 connectors F 01U 032 132 One 1 M2 5 Phillips pan screw F 01U 009 951 ...

Page 12: ...following instructions to install the VG4 SFPSCKT Fiber Optic module inside a VG4 Power Supply Box 1 Unpack the fiber optic module kit and remove the parts from the bag 2 Turn off the power to the VG4 power supply box and remove the cover 3 Remove the 6 pin connector from the P106 connector inside the power supply box if present Figure 2 1 P106 connector with 100 Ohm resistor ...

Page 13: ... Insert one plastic standoff pin into the hole on the main power supply board located to the left of the P107 Heater connector Figure 2 2 Insert standoff pin into power supply board 5 Connect the supplied power harness black to the J103 socket on the power supply board located below the Heater connector Figure 2 3 J103 socket location J103 ...

Page 14: ...into the metal base plate as shown below Figure 2 4 Placement of standoff pins in base plate 7 Align the upper right hole in the base plate to the standoff pin attached to the power supply box and press the base plate onto the pin Secure the base plate with the supplied screw in the lower left hole of the P105 connector Figure 2 5 Attach base place to power supply box ...

Page 15: ...Ensure that the bale clasp on the SFP module is up b Line up the SFP module with the port on the VG4 SFPSCKT module and slide it into the port until you hear the catches engage 9 Remove the rubber plug from the SFP module 10 Align the anchor holes on the fiber optic module to the standoff pins on the base plate and press the module onto the standoff pins until secure Figure 2 6 Attach Fiber Optic ...

Page 16: ...Dome pendant arm Note If installing a Pipe or Roof mounted AutoDome you will need to provide the appropriate length Ethernet cable with RJ45 connectors to reach between the AutoDome and the power supply box 13 Route the appropriate fiber optic cable through the conduit hole on the power supply box 14 Plug the fiber optic cable LC or SC connector into the SFP module inside the power supply unit 15 ...

Page 17: ...t No Power Check power to VG4 SFPSCKT If Green LED is present then Check power to CNFE2MC If Power LED is Green then check data link Invalid Fiber Link Check fiber connection to VG4 SFPSCKT If Red LED is present then the fiber link is missing If the LED is Flashing Red then Check the fiber connection to the CNFE2MC If the Link Act LED is not lit then the fiber link is missing ...

Page 18: ...nnector on the VG4 SFPSCKT If the right LED Green is not lit then no data is present at this RJ 45 connection If no LED lit on the RJ 45 connector then there is a fault with this connector the RJ 45 cable or the cable is not connected to the CNFE2MC Check the RJ 45 connector on the CNFE2MC If the right LED Green is not lit then no data is present at this RJ 45 connection If no LED lit on the RJ 45...

Page 19: ......

Page 20: ...curity Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 40 2577 284 Fax 31 40 2577 330 emea securitysystems bosch com www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosch com www boschsecurity com Bosch Security Systems Inc 2009 F 01U 134 924 1 0 2009 09 Data subject t...