background image

3.

Ventilation - Any openings in the unit enclosure are provided for ventilation to prevent
overheating and ensure reliable operation. Do not block or cover these openings. Do not
place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's
instructions have been adhered to.

4.

Object and liquid entry - Never push objects of any kind into this unit through openings
as they may touch dangerous voltage points or short-out parts that could result in a fire
or electrical shock. Never spill liquid of any kind on the unit. Do not place objects filled
with liquids, such as vases or cups, on the unit.

5.

Lightning - For added protection during a lightning storm, or when leaving this unit
unattended and unused for long periods, unplug the unit from the wall outlet and
disconnect the cable system. This will prevent damage to the unit from lightning and
power line surges.

6.

Controls adjustment - Adjust only those controls specified in the operating instructions.
Improper adjustment of other controls may cause damage to the unit. Use of controls or
adjustments, or performance of procedures other than those specified, may result in
hazardous radiation exposure.

7.

Overloading - Do not overload outlets and extension cords. This can cause fire or
electrical shock.

8.

Power cord and plug protection - Protect the plug and power cord from foot traffic,
being pinched by items placed upon or against them at electrical outlets, and its exit from
the unit. For units intended to operate with 230 VAC, 50 Hz, the input and output power
cord must comply with the latest versions of IEC Publication 227 or IEC Publication 245.

9.

Power disconnect - Units have power supplied to the unit whenever the power cord is
inserted into the power source, or when High Power-over-Ethernet (High PoE) power is
provided over the Ethernet CAT 5E/6 cable. The unit is operational only when the ON/OFF
switch is in the ON position. The power cord is the main power disconnect device for
switching off the voltage for all units. When High PoE or PoE+ (820.3at) is used to power
the unit, the power is provided over the Ethernet cable, which is then the main power
disconnect device for switching off the voltage for all units.

10. Power sources - Operate the unit only from the type of power source indicated on the

label. Before proceeding, be sure to disconnect the power from the cable to be installed
into the unit.
For battery powered units, refer to the operating instructions.
For external power supplied units, use only the recommended or approved power
supplies.
For limited power source units, this power source must comply with EN60950.
Substitutions may damage the unit or cause fire or shock.
For 24 VAC units, voltage applied to the unit's power input should not exceed ±10%, or
28 VAC. User-supplied wiring must comply with local electrical codes (Class 2 power
levels). Do not ground the supply at the terminals or at the unit's power supply terminals.
If unsure of the type of power supply to use, contact your dealer or local power company.

11. Servicing - Do not attempt to service this unit yourself. Opening or removing covers may

expose you to dangerous voltage or other hazards. Refer all servicing to qualified service
personnel.

12. Damage requiring service - Unplug the unit from the main AC power source and refer

servicing to qualified service personnel when any damage to the equipment has occurred,
such as:
the power supply cord or plug is damaged;
exposure to moisture, water, and/or inclement weather (rain, snow, etc.);
liquid has been spilled in or on the equipment;

AUTODOME 4000 Mini PTZ Dome

Safety EN | en

5

Bosch Security Systems, Inc.

Installation Manual

2015.08 | | Recessed Mount

Summary of Contents for VEZ-400 Series

Page 1: ...AUTODOME 4000 Mini PTZ Dome VEZ 400 Series en Installation Manual ...

Page 2: ......

Page 3: ...00 13 4 1 Overview 13 4 2 Parts List 13 4 3 Installing the Recessed Mount 13 4 4 Installing the Camera to the Recess Mount 16 5 Connection 19 5 1 Typical Wiring Configuration 20 5 2 RS 485 Connections 21 5 3 Video Connection 22 5 4 Alarm Connections 22 5 5 Power Connections 23 5 6 Camera Settings 23 5 6 1 Setting the address ID of the camera 24 5 6 2 Setting the protocol of the camera 24 6 Trouble...

Page 4: ... Warning Indicates a hazardous situation which if not avoided could result in death or serious injury Caution Indicates a hazardous situation which if not avoided could result in minor or moderate injury Notice Indicates a situation which if not avoided could result in damage to the equipment or environment or data loss Important Safety Instructions Read follow and retain for future reference all ...

Page 5: ...the power source or when High Power over Ethernet High PoE power is provided over the Ethernet CAT 5E 6 cable The unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect device for switching off the voltage for all units When High PoE or PoE 820 3at is used to power the unit the power is provided over the Ethernet cable which is then the ma...

Page 6: ...ctions Camera signal Protect the cable with a primary protector if the camera signal is beyond 140 feet in accordance with NEC800 CEC Section 60 Disposal Your Bosch product has been developed and manufactured using high quality materials and components that can be reused This symbol means that electronic and electrical devices that have reached the end of their working life must be disposed of sep...

Page 7: ...erates uses and radiates radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense Intentional or unintentional modifications not expre...

Page 8: ...elephone 585 421 4220 Fax 585 223 9180 or 717 735 6561 Email security repair us bosch com Canada Telephone 514 738 2434 Fax 514 738 8480 Europe Middle East Africa Region Please contact your local distributor or Bosch sales office Use this link http www boschsecurity com startpage html europe htm Asia Pacific Region Please contact your local distributor or Bosch sales office Use this link http www ...

Page 9: ...safest container in which to transport the unit and must be used if returning the unit for service Save it for possible future use Parts List Qty Description 1 AUTODOME 4000 Mini PTZ Dome camera 1 Drilling Template 4 6 x 30 mm plastic anchors 4 8 x 32 screws and attached O rings 4 M4 x 12 Torx screws and attached O rings 1 T20 Security Torx wrench 1 User Manual this booklet Warning Make sure that ...

Page 10: ... Drill with appropriate bit for pre drilling anchor holes Appropriate tool for cutting a hole in drywall or ceiling tile if applicable 2 2 10 en Unpacking AUTODOME 4000 Mini PTZ Dome 2015 08 Recessed Mount Installation Manual Bosch Security Systems Inc ...

Page 11: ...mber Description Application Drawing VEZ A4 IC AUTODOME 4000 In ceiling Mount Charcoal color and white color ceiling plate included where the camera is mounted into a recessed ceiling VEZ A4 PC AUTODOME 4000 Pipe mount Charcoal color where the camera is mounted to a horizontal high ceiling VEZ A4 PW AUTODOME 4000 Pipe mount White color 3 AUTODOME 4000 Mini PTZ Dome Installation Overview en 11 Bosc...

Page 12: ...n Electrical Code Part I also called CE Code or CSA C22 1 and all applicable local codes Bosch Security Systems Inc accepts no liability for any damages or losses caused by incorrect or improper installation Dimensions Ø112 4 41 Ø151 3 5 96 Ø154 6 06 26 1 02 79 3 11 138 5 43 mm in Figure 3 1 Dimensions Camera 4 Ø4 8 0 19 85 6 3 37 85 6 3 37 mm in Figure 3 2 Dimensions Mounting Holes 3 1 12 en Inst...

Page 13: ...se bleaching of the sensor s color filters This will be visible as colored spots in the picture and is irreversible Parts List The following table lists the parts included in the In ceiling recessed mount VEZ A4 IC Quantity Part 1 In ceiling mount VEZ A4 IC 1 White trim ring with 2 two M3 captive screws 1 Black trim ring with 2 two M3 captive screws 1 Security Torx wrench 1 Installation manual thi...

Page 14: ...h the crescent shape of the mounting plate and the crescent shape of the mounting bracket are aligned 5 Ensure that the clamping plates are angled inward by pushing up and into the two slots 6 Insert mount through the hole and into the ceiling Slide clamps out and down so that the drywall is clamped in between the clamps and the bracket flange 41 7 mm 1 64 in maximum ceiling thickness and 12 7 mm ...

Page 15: ...Over torquing the ceiling clamps can damage the clamp or ceiling Only tighten the clamp until it contacts the ceiling and you start to feel some resistance If using a power screwdriver set the torque level to the lowest setting AUTODOME 4000 Mini PTZ Dome Installing a Recessed Mount AUTODOME 4000 en 15 Bosch Security Systems Inc Installation Manual 2015 08 Recessed Mount ...

Page 16: ...NC COM NO multi color 3b 5 pin I O terminal Alarms and ground multi color 4 Video black with yellow connector 5 Cutout for cable 3 Attach the camera to the recess mount by removing the bubble from the camera use the wrench supplied with the camera and attaching the camera base to the mount using 4 M4 mounting screws with rubber ring supplied with the camera Ensure that the cable is aligned with th...

Page 17: ... this tether point 5 Align the trim ring so that the three alignment poles on the trim ring item 1 below align with the three mounting holes in the camera Align the two mounting screws attached to the trim ring item 2 below with the two mounting holes in the recess mount AUTODOME 4000 Mini PTZ Dome Installing a Recessed Mount AUTODOME 4000 en 17 Bosch Security Systems Inc Installation Manual 2015 ...

Page 18: ...ith the mounting holes in the recess mount 6 Fit the plastic trim ring Use the supplied T 10 Torx wrench to secure the trim ring s two 2 safety locking screws to the mounting bracket 18 en Installing a Recessed Mount AUTODOME 4000 AUTODOME 4000 Mini PTZ Dome 2015 08 Recessed Mount Installation Manual Bosch Security Systems Inc ...

Page 19: ...s are made Caution All wires for installation applications must be routed through a grounded conduit Caution To prevent humidity problems the camera must be installed in dry conditions and the cable leads should be sealed once connected 5 AUTODOME 4000 Mini PTZ Dome Connection en 19 Bosch Security Systems Inc Installation Manual 2015 08 Recessed Mount ...

Page 20: ...A 4a 5 pin I O terminal Alarms and ground 4b 3 pin I O terminal Alarm NC COM NO 5 2 pin data terminal RS 485 Connection 6 Video Out Female BNC connector 7 Video In to monitor Male BNC connector 8 CCTV Monitor 9 Bosch keyboard controller Note The box around several objects in the graphic above indicates that those devices are supplied separately 5 1 20 en Connection AUTODOME 4000 Mini PTZ Dome 2015...

Page 21: ...hielded Twisted Pair Distance 1 2 Km 3937 ft Gauge 0 511 mm 24 AWG Impedance 120 Ω Table 5 1 RS 485 Wire Specifications The following table shows the terminal connections for the 2 pin terminal block RS 485 connections see page 20 item 5 Number Signal Color 1 TRX Sky 2 TRX White Table 5 2 2 pin Terminal Block Connections Notice When the camera s RS 485 port is connected to a MIC BP3 Biphase conver...

Page 22: ...ra provides four alarm inputs and one alarm output Each input can be activated by dry contact devices such as pressure pads passive infrared detectors door contacts and similar devices The alarm output can activate an external device such as a buzzer Wire alarms either Normally Open N O or Normally Closed N C you must program the alarm inputs N O the default or N C through the on screen display me...

Page 23: ...er or a DVR by setting the Rotary and Dip switches Refer to the tables below for setting the camera s ID and selecting the protocol The camera s Dip switches can be accessed by removing the dome cover and are located on a PCB attached to the camera base Caution To prevent humidity problems the camera s dome cover must be removed only in dry conditions Caution When re mounting the dome cover to the...

Page 24: ...must have an unique address ID The default setting is 0 ID001 X0 X1 SW301 SW302 Table 5 6 Dome Camera ID Setting Rotary Switches SW301 SW302 Setting the protocol of the camera Set the protocol setting the baud rate and the termination setting of dip switch SW303 using the data in the tables below Note The value marked is the default setting 5 6 1 5 6 2 24 en Connection AUTODOME 4000 Mini PTZ Dome ...

Page 25: ... No 3 4 Dip Switch SW303 No5 Termination Off Off On On Table 5 9 Camera s RS 485 Termination Setting No 5 Dip Switch SW303 Notice When the RS 485 signal is looped through make sure that only the last device is properly terminated Improper RS 485 wiring or termination may result in unreliable system operation AUTODOME 4000 Mini PTZ Dome Connection en 25 Bosch Security Systems Inc Installation Manua...

Page 26: ... System Initialize Check the power rating of the power supply Measure the voltage at the camera since there could be a drop in voltage due cable length The power consumption increases when the camera is moving especially at high speed and when the heater is on The voltage at the camera should always be 24 VAC 10 The communication between controller and camera via RS 485 cable is not working proper...

Page 27: ... Password 9527 before setting a new password I cannot record a tour Check the size of the memory buffer Once the buffer reaches 100 the camera will not record a tour Clear the buffer to regain memory space Auto SensUp Max mode does not function Check that Enhancement function is enabled When this function is enabled AutoSenUp Max does not function I set WDR function but it is disabled Check that E...

Page 28: ...the datasheet for your camera available on the appropriate product pages of the Online Product Catalog at www boschsecurity com 7 28 en Technical data AUTODOME 4000 Mini PTZ Dome 2015 08 Recessed Mount Installation Manual Bosch Security Systems Inc ...

Page 29: ......

Page 30: ...urity Systems Inc 1706 Hempstead Road Lancaster PA 17601 USA www boschsecurity com Bosch Security Systems Inc 2016 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www boschsecurity com ...