8.5.5
38
en | Operation
EX65 Explosion-Protected Camera
Item
Selection
Description
Alarm output
VMD,
External
device,
Night mode
active,
Filter toggle
VMD: - output relay closes on VMD alarms.
External device: - make the output relay available to
remote communication devices.
Night mode active: - output relay closes when camera is in
monochrome mode.
Filter toggle: - output relay closes just before the IR filter
starts moving and opens when video level has stabilized (2
to 3 seconds)
EXIT
Returns to Install menu.
Connections submenu
Item
Selection
Description
Sync. input
High Z,
75 ohm
Select 75 ohm if the external sync input is not terminated
elsewhere.
Notch filter
On, Off
Switches notch filter on or off. The notch filter can
remove a Moiré pattern or color artifacts caused by
closely spaced vertical lines or objects (e.g. vertical
security bars over windows).
Bilinx Comms.
On, Off
If Off, Bilinx communications is disabled.
Camera buttons Enable,
disable
Enable or disable the camera buttons from working.
Cable
compensation
Off, Default,
RG59, RG6,
Coax12
Cable compensation is used to avoid the need for
amplifiers in long distance coaxial connections up to
1000 m (3000 ft). For optimum results select the coaxial
cable type used or, if unknown, select default.
Compensation
level
0,1,2 . . .+15 Sets the level of cable compensation
EXIT
Returns to Install menu.
2016.03 | 1.0 | F.01U.318.222
Installation Manual
Bosch Security Systems, Inc.
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]