Alarm inputs

The camera has a three-pole terminal block (fig. A-13) for connecting 
alarm sensors, such as doorcontacts. For normally open (N.O.) 
sensors, connect to contacts N.O.. For normally closed (N.C.) sensors, 
connect to contacts N.C..

Position

First you need to determine where the camera is to be installed. The 
best results are obtained when the camera looks a little downwards 
and not into a bright source of light.

Hold the camera in your hand at the spot where you want to 
install it and check on the monitor whether the camera does 
actually cover the required area from that spot.

Fasten the mounting bracket to the ceiling, the wall, or another 
even and firm surface by means of the supplied screws and plugs.

Tighten the knob (fig. A-3) of the ball-and-socket joint.

Fasten the camera to the bracket by screwing the mounting hole 
in the back or bottom of the camera (fig. A-1) onto the threaded 
end (fig. A-2).

Loosen the knob of the ball-and-socket joint (fig. A-3) and, if 
necessary, the screw (fig. A-4) on the mounting bracket and direct 
the camera accurately at the object or area you want to have on 
screen.

The knob and screw can be tightened again when the camera is 
in the required position.

Remark:

 The camera can also be mounted on any other camera 

tripod standardly provided with a 1/4" 20 UNC thread.

Check if the cable length compensation (fig. A-15) selector is set 
to the correct length. The length set must be the same as the 
length of the system cable (0-300m/900ft max.) connecting 
monitor and camera.

Summary of Contents for VCM8637/00T

Page 1: ...h Beobachtungskamera DE Installatiehandleiding Observatie Camera NL Manuale di installazione Telecamera di Osservazione IT Manual de Instalação Câmara de Observação PT Manual de instalación Cámara de Observación ES Installations manual Observationskamera DA Installationshandbok Bevakningskamera SV Asennusohje Valvontakamera SU Installasjons manual Overvåkingskamera NO ...

Page 2: ...Bosch Security Systems 2004 06 8637 8638 Installation Instructions Installation Instructions 1 2 5 3 4 00697 Figure A 12 100697 13 10 0 or 1 200m 0 50m 100m 300m 0 or 1 14 15 FIGURE A ...

Page 3: ...Bosch Security Systems 2004 06 8637 8638 Installation Instructions 5 4 3 2 4 5 2 3 5 4 3 2 4 5 2 3 5 4 3 2 5 4 3 2 R A E N R A F 1 FIGURE B ...

Page 4: ...ms 2004 06 8637 8638 Installation Instructions TABLE OF CONTENTS ENGLISH 2 FRANÇAIS 6 DEUTSCH 11 ESPAGÑOL 16 NEDERLANDS 21 ITALIANO 25 PORTUGUÊS 30 DANSK 35 SVENSKA 40 SUOMI 44 NORSK 48 GREEK 52 TECHNICAL SPECIFICATION 57 ...

Page 5: ...der test conditions that included use of system cables and connectors between system components If you have any problems contact your dealer WARNINGS Any unauthorized modification to this equipment may cause violation of the FCC rules resulting in the revocation of the authorization to operate the equipment To prevent fire or shock hazard do not expose this accessory to rain or moisture Do not att...

Page 6: ...all camera lines are scanned The monitor uses this to register the camera configuration of the system and to check whether any modifications have been made Sound If required the microphone incorporated in the camera can be switched off fig A 14 If an intercom box is included in the camera line the sound of camera and intercom box will be reproduced by the monitor WARNING Disconnect the monitor fro...

Page 7: ...o the ceiling the wall or another even and firm surface by means of the supplied screws and plugs Tighten the knob fig A 3 of the ball and socket joint Fasten the camera to the bracket by screwing the mounting hole in the back or bottom of the camera fig A 1 onto the threaded end fig A 2 Loosen the knob of the ball and socket joint fig A 3 and if necessary the screw fig A 4 on the mounting bracket...

Page 8: ...e system cable to the output of the camera fig A 12 The lens Focus range The built in lens provides an optimal image sharpness for objects between 1 metre and infinity depth of field Cable A 4 wire system cable see specifications is supplied standardly For an optimum picture and sound quality a dual twisted pair cable should be used CAUTION Do not touch the glass of the lens This could damage the ...

Page 9: ...pter between the monitor and the cameras is 300 meters TIPS FOR MAINTENANCE Cleaning The outside of the camera can be cleaned with a moist fluff free cloth or a shammy leather cloth When cleaning the objective a special lens cleaning cloth should be used Do NOT use cleaning fluids based on alcohol methylated spirit ammonia etc Avoid direct contact with water CAUTION The plugs used for the observat...

Reviews: