Bosch Ultima 862 Quick Reference Manual Download Page 18

 
Location 801 - 808 

RF Signal Strength  
For Devices 1 – 8 
 
 
 
 

 
Location 809 - 816 

RF Signal Strength 
For Devices 9 - 16

 

 
 
 
 
 

Location 900 

Default Options

 

 

Location 901 - 904 

System Time

 

 
 
 
Location 905 - 910 

System Date

 

 
 
 
 

Location 801 = Signal Strength For RF Device 1 
Location 802 = Signal Strength For RF Device 2 
Location 803 = Signal Strength For RF Device 3 
Location 804 = Signal Strength For RF Device 4 
Location 805 = Signal Strength For RF Device 5 
Location 806 = Signal Strength For RF Device 6 
Location 807 = Signal Strength For RF Device 7 
Location 808 = Signal Strength For RF Device 8 

801 802 803 804 805 806 807 808

0 0 0 0 0 0 0 0

D1 D2 D3 D4 D5 D6

D7

D8

Location 809 = Signal Strength For RF Device 9 
Location 810 = Signal Strength For RF Device 10 
Location 811 = Signal Strength For RF Device 11 
Location 812 = Signal Strength For RF Device 12 
Location 813 = Signal Strength For RF Device 13 
Location 814 = Signal Strength For RF Device 14 
Location 815 = Signal Strength For RF Device 15 
Location 816 = Signal Strength For RF Device 16 

809 810 811 812 813 814 815 816

0 0 0 0 0 0 0 0

D9  D10 D11 D12 D13 D14 D15 D16

0

0 = Defaulting System Allowed / 15 = Defaulting System Disabled 

Location 901 = Hour Of The Day (Tens Digit) 
Location 902 = Hour Of The Day (Units Digit) 
Location 903 = Minute Of The Day (Tens Digit) 
Location 904 = Minute Of The Day (Units Digit) 

901 

902  903 904

0 0  :

0 0

H H    M M 

Location 905 = Day Of The Month (Tens Digit) 
Location 906 = Day Of The Month (Units Digit) 
Location 907 = Month Of The Year (Tens Digit) 
Location 908 = Month Of The Year (Units Digit) 
Location 909 = Current Year (Tens Digit) 
Location 910 = Current Year (Units Digit) 

905 

906  907 

908  909 910

0 1  0 1  0 1

D D  M M  Y Y 

18 

Solution Ultima 862

 

Quick Reference Guide 

SOL ULTIMA 862 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited  

Summary of Contents for Ultima 862

Page 1: ...Solution Ultima 862 Quick Reference Guide ISSUE 1 70 ...

Page 2: ...may have been used Rather than put a trademark symbol in every occurrence of a trademark name we state that we are using the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringement of the trademark Notice of Liability While every precaution has been taken in the preparation of this document neither Bosch Security Systems Pty Limited nor any of...

Page 3: ... LOCATION 000 First location of the Primary Telephone Number To move to another programming location enter the location number followed by the key The data in the new location will now be displayed via the codepad indicators eg If you entered 34 the system will jump you to LOCATION 034 the beginning of the Subscriber ID Number For Receiver 1 To move to the next location press the key This will ste...

Page 4: ...Option Description 1 Dialler Reporting Functions Allowed 2 Remote Arming Via Telephone Allowed 4 Answering Machine Bypass Only When Armed 8 Use Bell 103 For FSK Format Disabled CCITT V21 Installer s Programming Commands These commands can only be used when you enter Installer s Programming Mode Enter the command followed by the key Command Description 958 Enable Disable Zone Status Hand Held Progr...

Page 5: ...o isolate followed by the key Repeat step 2 if more than one zone is required to be isolated 3 Press the key to exit when finished Code To Isolate 1 Press the key once 2 Enter your user code followed by the key 3 Enter the zone number that you want to isolate followed by the key Repeat step 2 if more than one zone is required to be isolated 4 Press the key to exit when finished Add Delete RF Devic...

Page 6: ...ed by the key Add RF Keyfob 1 Enter the Master Code followed by 1 and the key eg 2580 1 2 Enter the User Number 9 16 that you want to add followed by the key 3 Enter the 9 digit RF keyfob ID number followed by the key Delete A User Code RF Keyfob 1 Enter the Master Code followed by 1 and the key eg 2580 1 2 Enter the User Number 1 16 that you want to delete followed by the key 3 Press the key to d...

Page 7: ...ermine Fault 6 Communication Fail 1 Receiver 1 Fail Dialler 2 Receiver 2 Fail Dialler Modem Call Alarm Link 1 Press and hold the 6 key until two beeps are heard Latching Outputs Reset 1 Press and hold the 7 key until two beeps are heard Codepad Buzzer Tone 1 Press and hold the 8 key until the desired buzzer tone has been reached 2 Press the key to exit Test Report 1 Press and hold the 9 key until ...

Page 8: ... 0 0 0 0 0 0 0 0 0 0 0 0 0 1 HI LO Handshake Contact ID 4 No Handshake 2 1400 Hz Ademco TX 1900 Hz 5 Pager 3 2300 Hz Sescoa TX 1800 Hz 1 1 Contact ID 4 Domestic 7 Reserved 2 4 2 Expressed 5 Basic Pager 8 4 2 Pulsed 3 FSK 300 Baud 6 Reserved 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 HI LO Handshake Contact ID 4 No Handshake 2 1400 Hz Ademco TX 1900 Hz 5 Pager 3...

Page 9: ...vel Authority Level Description 0 Arm Disarm 1 Arm Only 2 Arm Disarm Open Close Reports 3 Arm Only Close Reports 4 Arm Disarm Code Required To Isolate 6 Arm Disarm Open Close Reports Code Required To Isolate 8 Master Code Arm Disarm 10 Master Code Arm Disarm Open Close Reports 12 Master Code Arm Disarm Code Required To Isolate 14 Master Code Arm Disarm Code Required To Isolate Open Close Reports 9...

Page 10: ... 296 297 298 299 300 301 Zone 05 0 0 0 1 14 1 1 Default Instant Zone Type Zone Pulse Count Zone Pulse Count Time Zone Options 1 Zone Options 2 Report Code Dialler Options Location 302 303 304 305 306 307 308 Zone 06 0 0 0 1 14 1 1 Default Instant Zone Type Zone Pulse Count Zone Pulse Count Time Zone Options 1 Zone Options 2 Report Code Dialler Options Location 309 310 311 312 313 314 315 Zone 07 1...

Page 11: ...t 2 Zone Isolation Allowed 4 Silent Alarm 4 Forced Arming Allowed 8 Sensor Watch 8 Zone Restore Report Allowed Zone Dialler Options Option Group 0 No Zone Reports Allowed 1 Report To Receiver 1 2 Report To Receiver 2 4 Report To Both Receiver 1 Receiver 2 8 Report To Receiver 2 Only If Receiver 1 Fails Keyswitch Zone Options The keyswitch zone options replace Zone Options 1 only for the zones that...

Page 12: ...ne Bypass Restore Report Location 331 Zone Trouble Report Location 332 Zone Trouble Restore Report 2 3 4 5 Location 333 Sensor Watch Report Location 334 Sensor Watch Restore Report 14 1 0 No Zone Status Reports Allowed 1 Report To Receiver 1 2 Report To Receiver 2 4 Report To Both Receiver 1 Receiver 2 8 Report To Receiver 2 Only If Receiver 1 Fails 0 Location 337 Increments Of 6 Hours 0 90 Hours ...

Page 13: ...ation 356 Tens Digit Location 357 Units Digit 10 8 Location 358 Tens Digit Location 359 Units Digit 10 2 Location 360 Tens Digit Location 361 Units Digit 10 7 Location 362 Tens Digit Location 363 Units Digit 10 1 Location 364 Tens Digit Location 365 Units Digit 10 6 Location 366 Tens Digit Location 367 Units Digit 368 369 370 6 7 12 Location 368 Code Retry Limit 0 Unlimited Location 369 Tens Digit...

Page 14: ...larm Enabled 4 1 Reserved 1 1 Telephone Line Fail 4 2 Reserved 1 2 Kiss Off Received 4 3 Reserved 1 3 Fuse Fail 4 4 Reserved 1 4 AC Fail 4 5 Chime 1 5 Low Battery 4 6 Zone Not Sealed 1 6 Horn Speaker Fail 4 7 Zone Not Sealed After Exit Time 1 7 Sensor Watch Alarm 4 8 Reserved 1 8 Codepad Medical Alarm 4 9 AC Mains Cycle 60 Hz Or 50 Hz 1 9 Codepad Fire Alarm 4 10 Area 1 Zone Unsealed Solution 880 O...

Page 15: ...se x the multiplier eg If you want the output to pulse one 1 second ON and five 5 seconds OFF you would program time base as one 1 and the multiplier as five 5 Solution Ultima 862 Quick Reference Guide 15 SOL ULTIMA 862 QUICK REF GUIDE Polarity Modes Option Description Option Description 0 Disabled 1 Normally Open Going Low 8 Normally Low Going Open 2 Normally Open Pulsing Low 9 Normally Low Pulsi...

Page 16: ... Increments Of 16 Seconds 0 240 Seconds 0 0 Location 420 Increments Of Days Tens Digit Location 421 Increments Of Days Units Digit 0 0 0 Location 422 Increments Of 10 Seconds 0 150 Seconds 5 Location 423 Increments Of 1 Minute 0 15 Minutes 7 Location 424 0 Slowest Frequency 15 Fastest Frequency 1 Location 425 Increments of 5 Minutes 0 75 Minutes Location 426 Hour Of The Day Tens Digit Location 427...

Page 17: ... 1 2 8 Zone Tamper Alarms To Be Silent 5 0 1 DS 304Mhz RF Receiver RF3212 2 Latching Keyswitch Input 3 Momentary Keyswitch Input 4 Reserved 0 0 1 Sound Siren On RF Receiver Fail 2 Sound Siren On RF Receiver Tamper Jamming 4 Unseal Zone That Fails Supervision If Supervision Enabled 8 RF Jamming Monitoring Allowed Location 528 Map RF Device 1 To Zone 1 To 8 Location 529 Map RF Device 2 To Zone 1 To ...

Page 18: ...tion 812 Signal Strength For RF Device 12 Location 813 Signal Strength For RF Device 13 Location 814 Signal Strength For RF Device 14 Location 815 Signal Strength For RF Device 15 Location 816 Signal Strength For RF Device 16 809 810 811 812 813 814 815 816 0 0 0 0 0 0 0 0 D9 D10 D11 D12 D13 D14 D15 D16 0 0 Defaulting System Allowed 15 Defaulting System Disabled Location 901 Hour Of The Day Tens D...

Page 19: ...00 meters 1000 feet LED On Module is functioning normally LED Off Power failure has occurred or module is not wired correctly Apply power to the control panel The red LED at the centre of the module will turn on LED Turns Off Momentarily Module acknowledged receiving an RF signal from a remote RF device RF Keyfob Operations For Solution Ultima Series Control Panels Figure 2 RF3332 2 Button RF Keyf...

Page 20: ...EOL Wiring Diagram With Tamper Location 266 14 Connections For Split EOL Resistors Using N O Contacts Figure 6 Split EOL Wiring Diagrams Using N O Contacts Wiring Diagram For Keyswitch Zone Figure 7 Wiring Diagram For Keyswitch Zone 20 Solution Ultima 862 Quick Reference Guide SOL ULTIMA 862 QUICK REF GUIDE DOCBosch Security Systems Pty Limited ...

Page 21: ...Wiring Diagram Figure 8 Solution Ultima Series Wiring Diagram Solution Ultima 862 Quick Reference Guide 21 Electronics Design and Manufacturing Pty LimitedSOL ULTIMA 862 QUICK REF GUIDE D ...

Page 22: ...Component Overlay Figure 9 Solution Ultima Series Component Overlay 22 Solution Ultima 862 Quick Reference Guide SOL ULTIMA 862 QUICK REF GUIDE DOCBosch Security Systems Pty Limited ...

Page 23: ......

Reviews: