1 2
|
Installation Manual
Bosch Tronic 5000T Electric Water Heaters - BTC 724001301 A (10.2021)
Temperature & Pressure Relief Valve
The temperature & pressure relief valve:
Must not be in contact with any electrical part
Must be connected to a proper discharge line which terminates at an
adequate drain.
Must not exceed the working pressure shown on the data plate of the water
heater.
Must be of materials listed for hot water distribution.
Manually operate the temperature and pressure relief valve at least once a year to
make sure it is working properly To prevent water damage the valve must be properly
connected to a discharge line which terminates at an adequate drain.
Standing clear of the outlet (discharged water may be hot), slowly lift and release
the lever handle on the temperature and pressure relief valve to allow the valve to
operate freely and return to its closed position. If the valve fails to completely reset
and continues to release water, immediately shut off the electrical power and the cold
water inlet valve and call a qualifi ed service technician.
Figure 3
Manual Relief
Level
Temperature
& Pressure
Relief Valve
Discharge Line
to Drain
Discharge Line
WARNING: SCALD HAZARD, PROPERTY DAMAGE
Discharging water may be hot and can cause scald injuries
and property damage. Discharge lines must be properly
installed and piped to an adequate drain.
The discharge line:
Must not be smaller than the pipe size of the relief valve.
Must not be capped, blocked, plugged or contain any valve between the
relief valve and the end of the discharge line.
Must terminate 6 inches above a floor drain or external to the building.
Must be capable of withstanding 250°F ( 121°C) without distortion.
Must be installed to allow complete drainage of both the temperature and
pressure relief valve and discharge line.
Figure 4
7.7 Recirculating Lines
In some installations a return circulation line may be installed. The recirculation line
can be connected to the drain valve or cold water inlet connection using a tee.
7.8 Turning on Water to Heater
After piping and hook-ups are completed, open all hot water outlets. Open cold water
inlet valve to fi ll tank. As each hot water outlet delivers water free from air, it can be
shut off . Check the system for leaks.
WARNING: SHOCK HAZARD
Be careful not to allow escaping water to contact electrical
wires.