6 720 647 005 (2014/04)
TRONIC 3000C Pro
10 | Installation
4.3.1 Water quality
Water quality can have an impact on appliance longevity and
may not be covered under the manufacturer's warranty.
▶ For water analysis data call your local water department, or
if on a well, have well water analyzed periodically.
If water quality exceeds one or more of the values specified
below, Bosch recommends consulting a local water
treatment professional for water softening/conditioning
options.
4.4
Electrical connections
Connecting the unit to power
▶ Strip back the insulation on the power wires about
3/8". Any insulation on the ground should be stripped back
about 3/4".
▶ Feed the cable through the cover bottom or backplate rear
entry grommets, as appropriate.
▶ Connect the cables to the terminal block and ground stud
(Fig. 4 ):
Fig. 4
Cable termination
[1]
Ground
[2]
Rubber sleeve
▶ Make sure that all the terminal block screws are tightened
securely. Loose connections can cause wires to heat up.
▶ Make sure that the ground wire is wrapped around its
terminal stud and into the saddle washer. The nut should be
tightened securely.
Description
Max. Levels
pH
pH
6.5 - 8.5
TDS (total Dissolved
Solids)
mg/l or ppm
500
Total hardness
mg/l or ppm
100
(6 grains)
Aluminum
mg/l or ppm
2.0
Chlorides
mg/l or ppm
250
Copper
mg/l or ppm
1.0
Iron
mg/l or ppm
0.3
Manganese
mg/l or ppm
0.05
Zinc
mg/l or ppm
5.0
Table 5
WARNING:
▶ The unit must be installed by a qualified
electrician.
▶ The unit must be grounded.
▶ Connect the unit to power.
Model
Rated Voltage
(V)
Rated Current
(A)
Recommend
Wire Size (AWG)
US3
110
30
10
US6
277
25
10
US7
240
30
10
US9
208
35
8
US9
240
40
8
Table 6
NOTICE:
When the Tronic 3000C Pro is not within
sight of the electrical circuit breakers, a
circuit breaker lockout or additional local
means of disconnection for all non grounded
conductors must be provided that is within
sight of the appliance. (REF NEC 422.31)