en
Troubleshooting
44
Fault
Cause
Troubleshooting
Appliance door opens too
wide at the end of the pro-
gramme.
Door is not correctly adjus-
ted.
▶
Adjust the appliance door as de-
scribed in the installation instruc-
tions.
The door gap must be at least
70 mm - 100 mm.
Wrong screws used to ad-
just the door gap.
▶
Use size 4X30 bolts to adjust the
door gap.
The bolts are included in the scope
of supply.
If you use bolts that are too long,
this can deactivate the function of
automatic door opening.
Error code / Fault display / Signal
Fault
Cause
Troubleshooting
E:20-60 lights up alternately. Appliance has detected cal-
cified heating element.
1.
Descale the appliance.
2.
Operate the appliance with the wa-
ter softening system.
1
E:30-00 will light up altern-
ately.
Water protection system is
activated.
1.
Turn off the water tap.
2.
E:31-00 will light up altern-
ately.
Water protection system is
activated.
1.
Turn off the water tap.
2.
E:34-00 will light up altern-
ately.
Water is continuously run-
ning into the appliance.
1.
Turn off the water tap.
2.
E:32-00 will light up altern-
ately or indicator for water
supply lights up.
Supply hose is kinked.
▶
Install the supply hose without
kinks.
Water tap is turned off.
▶
Turn on the water tap.
Water tap is jammed or
furred up.
▶
Turn on the water tap.
The flow rate must be at least 10 l/
min when the water supply is open.
The filters in the water con-
nection of the supply or
AquaStop hose are blocked.
1.
Switch off the appliance.
2.
Pull out the mains plug.
3.
Turn off the water tap.
4.
Unscrew the water connection.
1
Depending on the appliance specifications