en
Water softening system
24
4.
Place the lid back on the dis-
penser and turn to close.
Switching off water softening
system
Note
To avoid damage to the appliance, only
switch off the water softening system in
the following cases:
¡
The water hardness is max. 26 °E
and you are using combined deter-
gents with salt replacement sub-
stances. According to manufactur-
ers, combined detergents with salt
replacement substances can gen-
erally only be used up to a water
hardness of 26 °E without adding
special salt.
¡
The water hardness is 0 - 8 °E.
You do not need to use special
salt.
1.
Press .
2.
To open the basic settings, press
for 3 seconds.
a
The display shows H:xx.
a
The display shows
.
3.
Press or repeatedly until the
display shows H:00.
4.
To save the settings, press
for 3 seconds.
a
The water softening system is
switched off and the salt refill indic-
ator is deactivated.
Regeneration of the water
softening system
In order to obtain fault-free function of
the water softening system, the appli-
ance performs reheating of the water
softening system at regular intervals.
Regeneration of the water softening
system takes place before the end of
the main rinse cycle in all pro-
grammes. It will increase the run time
and consumption values, e.g. water
and electricity.
Overview of consumption values with regeneration the water softening
system
Here you can find an overview of the maximum additional running time and
consumption values during regeneration of the water softening system.
You can find the column applicable to your model in the quick reference guide
according to its water consumption in the Eco 50° programme.
Water consump-
tion in litres (de-
pending on
model)
Regeneration of
the water soften-
ing system after
x rinse cycles
Additional run-
ning time in
minutes
Additional water
consumption in
litres
Additional power
consumption in
kWh
8
5
4
2.5
0.03
9
4
4
2.5
0.03
The consumption values specified
are laboratory measurements determ-
ined in accordance with the currently
applicable standard and using the
Eco 50° programme and the factory
value of the water hardness is set to
16 - 20°E.