3.0 Setup
1. Carefully open the service door (
Item 3
in
Figure 4
)
and insert the two AA batteries (supplied),
observing the correct polarity.
2. Select a mounting location (refer to
Section 2.0
Installation Considerations
on page 3).
3. Temporarily mount the unit so you can remove it
as needed.
3.1 Sensitivity
Setting
1. If the front housing is attached, carefully open the
service door (
Item 4
in
Figure 5
).
2. Enable the LEDs for test purposes by sliding the
LED ENABLE switch (
Item 5
in
Figure 5
) in the
direction the arrow points (above the switch). An
orange flag protrudes from the side of the
RF1100E.
Figure 4: RF1100E Front Layout
8
9
3
5
7
6
1
EVENT
4
2
1 - Service door tamper switch
2 - AA batteries
3 - Service Door
4 - SW4 test mode pads
5 - SW3 sensitivity DIP switches
6 - Alarm LED
7 - Event LED
8 - LED enable switch (off position)
9 - Housing screw
Figure 5: Sensitivity switch
EVENT
3
2
4
5
1
1 - SENS1
2 - Test pads
3 - SENS2
4 - Service door
5 - LED enable switch
(shown in the OFF
position)
3. Determine the sensitivity setting for your
application from
Table 1
.
Table 1: RF1100E Sensitivity Settings
Sensitivity SENS1 SENS2 Approximate
Range
Maximum
OFF
OFF
7.6 m
Medium ON OFF 4.6
m
Low
OFF
ON
3 m
Lowest ON ON 1.5
m
4. Use a small screwdriver to move the sensitivity
switches. Use the settings determined in
Step 3
.
5. Turn on any sources of noise (such as machinery,
office, or audio equipment) in the area.
6. Observe the green event LED (
Item 7
in
Figure 8
)
for approximately 1 min. If the green LED flashes,
relocate the unit or reduce the sensitivity by
adjusting the sensitivity switch.
7. Repeat
Steps 3
through
6
until you achieve the best
sensitivity level.
8. After setting the sensitivity, slide the LED enable