Bosch RF1100E Installation Instructions Manual Download Page 4

RF1100E

 | Installation Instructions | 3.0  

Setup 

 

 

Bosch Security Systems | 6/04 | 4998138687C 

 

3.0   Setup 

1.  Carefully open the service door (

Item 3

 in 

Figure 4

and insert the two AA batteries (supplied), 
observing the correct polarity. 

2.  Select a mounting location (refer to 

Section 2.0 

Installation Considerations

 on page 3). 

3.  Temporarily mount the unit so you can remove it 

as needed. 

3.1 Sensitivity 

Setting 

1.  If the front housing is attached, carefully open the 

service door (

Item 4

 in 

Figure 5

). 

2.  Enable the LEDs for test purposes by sliding the 

LED ENABLE switch (

Item 5

 in 

Figure 5

) in the 

direction the arrow points (above the switch). An 
orange flag protrudes from the side of the 
RF1100E. 

 

Figure 4:  RF1100E Front Layout 

8

9

3

5

7

6

1

EVENT

4

2

1 -   Service door tamper switch  
2 -  AA batteries 
3 -   Service Door 
4 -   SW4 test mode pads 
5 -   SW3 sensitivity DIP switches 
6 -   Alarm LED 
7 -   Event LED 
8 -   LED enable switch (off position) 
9 -   Housing screw 

 

Figure 5:  Sensitivity switch 

EVENT

3

2

4

5

1

 

1 -  SENS1 
2 -  Test pads 
3 -  SENS2 

4 -  Service door 
5 -  LED enable switch 

(shown in the OFF 
position) 

 

3.  Determine the sensitivity setting for your 

application from 

Table 1

 

Table 1:  RF1100E Sensitivity Settings 

 

Sensitivity SENS1  SENS2  Approximate 

Range 

Maximum 

OFF 

OFF 

7.6 m 

Medium ON  OFF  4.6 

Low 

OFF 

ON 

3 m 

Lowest ON  ON  1.5 

 

4.  Use a small screwdriver to move the sensitivity 

switches. Use the settings determined in 

Step 3

5.  Turn on any sources of noise (such as machinery, 

office, or audio equipment) in the area.  

6.  Observe the green event LED (

Item 7

 in 

Figure 8

for approximately 1 min. If the green LED flashes, 
relocate the unit or reduce the sensitivity by 
adjusting the sensitivity switch. 

7. Repeat 

Steps 3

 through 

6

 until you achieve the best 

sensitivity level. 

8.  After setting the sensitivity, slide the LED enable 

switch (

Item 5

 in 

Figure 5

) to the OFF position. 

Summary of Contents for RF1100E

Page 1: ...EN Installation Instructions Wireless Glass Break Transmitter RF1100E ...

Page 2: ...ell is a registered trademark of The Gillette Company Eveready is a trademark of Eveready Battery Company Inc Panasonic is a registered trademark of Matsushita Electric Industrial Co Ltd Figure 1 RF1100E Mounting Template Actual size 3 2 2 1 1 Wall tamper screw optional 2 Mounting screw 3 Base of RF1100E ...

Page 3: ...ere is no minimum range at least 2 m from the floor at least 1 m from forced air ducts at least 1 m from sirens or bells greater than 5 cm in diameter on a window frame if any heavy window covering is present Avoid mounting the detector in a corner on the same wall as the protected glass on free standing posts or pillars in rooms with noisy equipment such as air compressors bells and power tools T...

Page 4: ...e pads 5 SW3 sensitivity DIP switches 6 Alarm LED 7 Event LED 8 LED enable switch off position 9 Housing screw Figure 5 Sensitivity switch EVENT 3 2 4 5 1 1 SENS1 2 Test pads 3 SENS2 4 Service door 5 LED enable switch shown in the OFF position 3 Determine the sensitivity setting for your application from Table 1 Table 1 RF1100E Sensitivity Settings Sensitivity SENS1 SENS2 Approximate Range Maximum...

Page 5: ...gure 6 The tester buzzes and the green LED on the RF1100E flashes once per second If the green LED does not flash move closer to the detector and repeat the procedure 3 2 2 Testing the Detector Flex and Audio Signals 1 Set the 13 332 tester switches to the TEST Item 2 in Figure 6 and FLEX positions Item 4 in Figure 6 2 Press the red Start button Item 3 in Figure 6 The tester activates and starts a...

Page 6: ...e pads 7 AA alkaline batteries 8 Battery housing 1 Open the service door Item 3 in Figure 8 on page 6 2 Remove the housing screw Item 9 in Figure 8 located near the LED ENABLE switch Item 8 in Figure 8 3 Lift the end of the cover off the base near the housing screw Item 9 in Figure 8 on page 6 4 Use the mounting template Figure 1 on page 2 to mark the mounting holes and tamper screw hole optional ...

Page 7: ... your control panel s programming guide for programming information on wireless type devices 7 0 Specifications Table 2 RF1100E Specifications Dimensions 12 2 cm x 10 6 cm x 3 2 cm Operating Temperature 0 C to 50 C Frequency 433 42 MHz Operating Voltage 3 V Battery Life At least two years under normal operating conditions Test with the recommended battery types Duracell MN1500 or PC1500 Eveready E...

Page 8: ... 2004 Bosch Security Systems 4998138687C Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 ...

Reviews: