534
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
7.2.7
Motor-breaker
in chapter
.
7.2.8
Switching on the tightening cell
7.2.8.1
Compact system
LED displays
Fig. 7–9:
LED on the front
NOTICE
Overvoltage
Components may be damaged
The CS on/off switch may only be switched on once all the cables have been connected and
checked for proper fit.
Table 7–6:
LED modes
LED
Display
Diagnosis
Off
No power supply or low-voltage power supply
available
Blue
Power supply and low-voltage power supply
available
Green
Ready for operation
Green, flashing
Sequence control active, not ready for operation,
no system error
Red, flashing
System error
OK/NOK
Green
Tightening case evaluation: OK
Red, flashing
Tightening case evaluation: NOK
Off
Motor contactor not operated
Green
Motor contactor operated
Red/green, flashing
Servo amplifier initialization
Red
Motor contactor error
FG
Green
Servo amplifier release
Off
No servo amplifier release
RUN/STOP
(only for
CS... IL)
Green
IndraLogic running
Red
IndraLogic stopped
ERROR
(only for
CS... IL)
Red, flashing
IndraLogic error
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...