3 608 878 300
Tightening Technology |
Bosch Rexroth AG 303
System 350
| 3 608 878 300/2019-03
The field bus master must be programmed in a way that bytes 115 to 118 are evaluated as a torque value
for the second channel.
6.4.4.6
Example of results output with field bus
The following example is to clarify the assignment of the parameters and the results values.
The result is displayed in clear text in Figure
displays the contents of the storage area
in hexadecimals. The contents of the data buffer are assigned to the results in Table
; the meaning
of the results is displayed in Table
.
Fig. 6–55:
Test of the results output via the
System test
CS field bus data
function
Table 6–53:
Address
(length)
0 (4)
4 (82)
86 (7)
93 (15)
108 (15)
115 (4)
123 (15)
138
Control sign
al o
u
tput
Appl
ication block
FO 1
Appl
ication res
u
lt
in
FO 2
1
s
t ch
an
ne
l re
su
lt
fr
om
a
ppli
c
a
tion
in
FO 2
2n
d ch
an
ne
l re
su
lt
fr
om
a
ppli
c
a
tion
in
FO 2
Actual torque
0:T
3rd ch
a
nne
l re
sult
fr
om
a
ppli
c
a
tion
in
FO 2
KE erro
r
Example
The last step of the tightening program was programmed with the following parameters:
•
Target function Torque 100 Nm
•
Monitoring function Torque:
– Lower limit 98 Nm
– Upper limit 102 Nm
•
Target function Angle:
– Lower limit 50 degrees
– Upper limit 250 degrees
IMpdp interface:
•
Number of I/O points: 16I+16O
•
Receive data 16 bytes
•
Send data 103 bytes
Summary of Contents for Rexroth Tightening System 350
Page 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Page 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Page 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...