RE 30011-B, Edition 10.2021, Bosch Rexroth AG
Mounting |
Pressure and flow control system SYDFE1 series 2X, 3X
55/96
32a
26a
U
B
18 .... 36 V
0 V
8c
10c
U
U
28a
VT5041-3X/..
Signal 0 - 10 V
Fig. 24: Connection pattern for pressure transducer
HM20...H...
7.6.4 Connecting the valve position transducer
Basically, the pinout of the VT 5041-3X has remained unchanged compared with
version VT 5041-2X, i.e. control electronics VT 5041-3X can sense the position
transducer signal according to the specification of the VT 5041-2X without
requiring a different sensor cable.
Make certain that jumper J8 is set on control electronics VT 5041-3X.
VT5041-2X...
Fig. 25: Connection pattern of the valve position transducer in conjunction with VT5041-2X...
(old systems)
The following is valid for all new systems:
In the case of cable lengths up to 50 m the connection can be established
using a standard cable. Make certain that jumper J8 is set on control
electronics VT 5041-3X.
Recommended cable type: LiYCY 5 x 0.25 mm²
VT5041-2X...