Installation 57/78
RE 66170-B/2019-05-15, Control block SB24/34, Bosch Rexroth AG
1.
Observe the requirements for the contact surface in the offer drawing.
2.
Always attach the control block/control block segment at all dedicated
mounting points.
3.
Tighten the mounting screws clockwise using a torque wrench in accordance
with Table 34.
Table 34: Tightening torques
Screw
Tightening torque
Minimum screw-in
depth of the thread
Through bore diameter Ø
M10
40
+8
Nm
15 mm
11
+0.2
mm
Fig. 5: Control block mounting
7.6.3 Completion of assembly
▶
Remove the transport protection.
If necessary, the control block/control block segment may be delivered with
protective covers and protective plugs. They are not pressure-resistant and
have to be removed prior to connection.
7.6.4 Mechanical connection of the control block/control block segment
Connection of actuation elements including tolerances is illustrated in the offer
drawing. The tightening torques are to be selected according to the actuation
elements. There must not occur any radial forces during actuation!
Installation