16
/18
Load-sensing control block SB11
| Repairing the flange surface
Bosch Rexroth AG, RE 66177-10-R/2021-11-16
6�2 Repairing the shuttle valve
Table 8: Parts list
Position
Designation
Shuttle valve
O-ring
1�
Remove the O-ring from port
Y
.
2�
Remove the shuttle valve from port
Y
.
3�
Align the shuttle valve with the spherical sealing cup to port
Y
and insert
without jamming.
4�
Check the distance dimension 0.5 mm from the flange surface of the control
block segment to the upper edge of the inserted shuttle valve.
5�
Insert a new O-ring into port
Y
.
NOTICE!
The shuttle valve must remain freely movable within the O-ring .
Disassembly/assembly,
shuttle valve