1070080029 / 05
Bosch Rexroth AG
Electric Drives
and Controls
PST 6xx0
|
|
196
/330
General information on damage to property and products
3.3
Electrical connection
NOTICE
Incorrect voltage supply
Possibility of damage to the electrical equipment!
"
Check whether the supply voltage coincides with the nominal vol
tage indicated on the nameplate of the product!
The product may only connected to the mains if these values coin
cide.
"
Make sure that fluctuations or deviations of the supply voltage
from the nominal value always range within the permitted tole
rance limits (refer to technical data).
Capacitive or inductive interferences in the cables
Possibility of function disturbances!
"
Install the power lines and control cables separately.
The following clearances are recommended:
> 100 mm with parallel installation of cables < 10m,
> 250 mm with parallel installation of cables > 10m.
"
The product should be installed in close proximity to the welding
equipment in order to keep the lengths of the necessary connec
tion cords to a minimum
.
Plugging or unplugging modules or connectors/terminals into/from
live systems
Possibility of damage to the electrical equipment, unexpected
plant reactions!
"
Unless described otherwise, never unplug or plug any connec
tors/terminals on live systems.
"
The timer's power supply should always be disconnected before
inserting/removing any timer modules.
ENGLISH
Summary of Contents for Rexroth PST 6 0 Series
Page 12: ......
Page 152: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 152 330 Notizen Notes ...
Page 170: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 170 330 Notes ENGLISH ...
Page 176: ......
Page 316: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 316 330 Notes DEUTSCH ...
Page 320: ...1070080029 05 Bosch Rexroth AG Electric Drives and Controls PST 6xx0 320 330 Notes DEUTSCH ...