3 608 870 A47
Tightening Technology |
Bosch Rexroth AG 163
Nexo cordless Wi-Fi nutrunner
| 3 608 870 A47/2019-10
Fig. 7–3:
IPM architecture
Before transmission of the tightening results and tightening graphs via the Rexroth IPM Protocol, the data
are converted into the format used by the IPM process data and analysis system. In this format, tightening
channel and tightening program are used for the identification of a measurement point, the so-called
"work sequence" (AFO). By means of the assignment between tightening channel/tightening program
and AFO, the physical process information and process data is then assigned to the logical features. This
assignment is defined and managed by configuring it in the NEXO-OX operating system. The number of
data records is also configured via the NEXO-OS operating system, using the
Settings
Data
Results storage
.
7.6.1
Message structure
Table
shows the basic structure of a message of the Rexroth IPM Protocol.
Browser
Web server
Database
Database server
IPM server (1…n)
IPM gateway
(1…n)
Access point
Nexo
Table 7–60:
Rexroth IPM Protocol message structure
Message component
Element
Element description
Comment
Header
AFO
AFO description
For identification of a work
sequence (AFO) and/or
tightening position
Name
AFO name