4
Technical Data
4.1
Characteristics
4.1.1
General Information
The speed-torque curves and the technical data are specified for different
motor overtemperatures.
The motor data and characteristic curves are determined using MKE motors
under the following conditions:
●
Environmental temperature max. 40 ℃
●
Insulated structure (aluminum flange)
●
In case of motors with the optional holding brake, the data are always
specified for motors with a holding brake.
●
Motors with radial shaft sealing ring
4.1.2
Operating Modes
The motors are documented according to the test criteria and measuring
methods of EN 60034-1. The specified characteristic curves correspond to
operating mode S1 or S3.
P
Load
P
V
Electric losses
Θ
Temperature
Θ
max
Highest temperature (motor housing)
t
Time
T
C
Cycle time
Δt
P
Operating time with constant load
Δt
V
Idling time
Fig.4-1:
Operating modes according to EN 60034-1:1998
4.1.3
Duty Cycle
Operating mode S6 is supplemented by specification of the ON time (ED) in
%. The duty cycle is calculated as follows:
DOK-MOTOR*-MKE*GEN2***-PR06-EN-P
Rexroth MKE Synchronous Motors for Potentially Explosive Areas acc. to ATEX and UL/CSA
Bosch Rexroth AG
23/135
Technical Data