9.7.7
Liquid cooling system
General information
Machines and systems can require liquid cooling for one or more drive com‐
ponents. If several liquid-cooled drive components exist, they are connected
to the heat removal device via a distribution unit.
motor
motor 1
motor 2
motor 3
motor 4
he a t re mova l de vice
he a t
output
he a t
output
control ca bine t a ir
coole r
coola nt te mpe ra ture
controlle r
control
coola nt line s
dis tributor
ca bine t
Fig. 9-9:
General arrangement of cooling systems with one and more drive
components
Heat removal device
The heat removal device dissipates the total heat that was fed into the liquid
into a superordinate coolant. It provides a temperature-controlled coolant and
thus maintains a required temperature level at the components that are to be
cooled.
There are three different types of heat removal devices. They are identified
by the type of the heat exchanger between the different media:
1.
Air-to liquid cooling unit
2.
Liquid-to-liquid cooling unit
3.
Cooling unit
A heat removal device includes a heat exchanger, a coolant pump and a
coolant container (see
fig. 9-10 "Heat removal devices" on page 272
).
MBT High Synchronous Torque Motors
271/409
Application notes
R911298798_Edition 08 Bosch Rexroth AG
Summary of Contents for rexroth MBT
Page 1: ...MBT High Synchronous Torque Motors Project Planning Manual R911298798 Edition 08 ...
Page 18: ...6 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 32: ...20 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 240: ...228 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 298: ...286 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 416: ...404 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Page 421: ...Notes MBT High Synchronous Torque Motors 409 409 ...