Fastening the cover
1. Check that the seal of the cover is not damaged.
2. Position the cover properly and fasten the screws with the corresponding
tightening torque (refer to
tab. 10-2 "Tightening torques" on page 20
).
Cable grommets ate the Embedded Terminal VEP 30.5DPU...
●
To maintain the degree of protection IP 54, use only cable grommets that fit
the cable cross-sections for cable bushing. Also refer to the following table:
Cable grommet name
(Assembling kit/putty)
Cable diameter
QT4
4-5 mm
QT5
5-6 mm
QT6
6-7 mm
QT7
7-8 mm
QT8
8-9 mm
QT11
11-12 mm
QT12
12-13 mm
QTB
Dummy sleeve
Tab. 10-3: Cable diameter and corresponding cable grommets
10.4.1 Mounting at standardized VESA support arm
Observe the minimum bending radius of the cables used.
Use appropriate cable material (sufficient bending and torsional
strength).
Embedded Terminals with Profibus DP
Master
Bosch Rexroth AG
Mounting, demounting and electric installation
DOK-CONTRL-VEP*XX.5***-IT01-EN-P
23/41