
To create a mounting cut-out and to install the Embedded Terminal, proceed as
follows:
1. Create a mounting cut-out with the corresponding number of holes with a
diameter of 4 mm, refer to
fig. 10-5 "Mounting dimensions of the VEP
30.5EFU in millimeters" on page 21
2. Insert the Embedded Terminal from the front into the cut-out and insert
the mounting bolts M4 into the drilled holes.
3. Fasten the Embedded Terminal by screwing the nuts at the rear side of the
mounting bolts.
1
1
①
Mounting bolt
Fig. 10-4: Rear view: Position of the mounting bolts (exemplary illustration)
Damage to the mechanics caused by wrong
tightening torque.
NOTICE
Tighten the screws acc. to the following table.
Thread
Tightening torque
M2,5
0.4 Nm
M3
0.7 Nm
Bosch Rexroth AG
Mounting, demounting and electric installation
Embedded Terminals with Profibus DP
Master
20/41
DOK-CONTRL-VEP*XX.5***-IT01-EN-P