Rexroth IndraDrive
Status Diagnostic Messages
6-13
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
A0102 Position mode with encoder 1
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is in position control. The position control loop is closed by
means of a position encoder in the drive. The master only specifies the
position command value characteristic, the drive follows the command
value with a lag error.
"Encoder 1" means that the encoder assigned by means of
P-0-0077,
Assignment motor encoder->optional slot
is used as a control
encoder.
See also Functional Description "Position Control with Cyclic Command
Value Input"
A0102 - Attributes
Display:
AF
Mess. no.:
A0102 (hex)
A0103 Position mode with encoder 2
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The drive is in position control. The position control loop is closed by
means of a position encoder in the drive. The master only specifies the
position command value characteristic, the drive follows the command
value with a lag error.
"Encoder 2" means that the encoder assigned by means of
P-0-0078,
Assignment optional encoder->optional slot
is used as a control
encoder.
See also Functional Description "Position Control with Cyclic Command
Value Input"
A0103 - Attributes
Display:
AF
Mess. no.:
A0103 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01