9-64
Command Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C0255 Safety command for system init. incorrect
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the transition check from communication phase
3 to
communication phase 4 (C0200) the optional safety technology module is
initialized and a timeout check is run for the module.
Cause
Remedy
Sporadic timeout error
Reset optional safety technology module and contact
our service department
Firmware defect on optional safety technology
module
If command error occurs repeatedly, safety technology
firmware has to be replaced
Hardware defect on optional safety technology
module
If command error occurs repeatedly, optional safety
technology module has to be replaced
Note:
Only Rexroth service engineers are allowed to replace optional
modules of the control section.
For removing command errors see "Command Errors"
See also documentation "Integrated Safety Technology", keyword
"Firmware Update"
C0255 - Attributes
Display:
C0255
Mess. no.:
C0255 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01