Overview of Operating Modes
Supported Operating Modes
The drive firmware MPX-02 supports the following operating modes:
•
torque/force
control
•
velocity
control
•
position control with cyclic command value input
•
drive-internal
interpolation
•
drive-controlled
positioning
•
positioning block mode
•
synchronization
modes:
•
velocity synchronization with real/virtual master axis
•
phase synchronization with real/virtual master axis
•
electronic cam shaft with real/virtual master axis
Note:
The operating modes supported by the firmware are
depending on the hardware and firmware and are contained in
parameter
S-0-0292, List of all operating modes
.
Operating Mode Handling
Selecting the Operating Mode
It is possible to configure up to 4 different operating modes (see also
S-0-0292) in the drive. Assignment and configuration are made via the
following parameters:
•
S-0-0032, Primary mode of operation
•
S-0-0033, Secondary operation mode 1
•
S-0-0034, Secondary operation mode 2
•
S-0-0035, Secondary operation mode 3
Note:
If the value "0" was entered in one of these parameters, the
F2007 Switching to non-initialized operating mode
error
message is generated when this operating mode is activated.
The operating mode is activated and controlled via bits 8 and 9 in
parameter
P-0-0116, Device control: control word
:
•
bit 8/9 = 00:
primary mode of operation activated
•
bit 8/9 = 01:
secondary operating mode 1 activated
•
bit 8/9 = 10:
secondary operating mode 2 activated
•
bit 8/9 = 11:
secondary operating mode 3 activated
Activating the Operating Mode