In operation
Transport
Storage
Mechanical strength
Max. vibration:
Frequency range:
10...150 Hz
Excursion: 0.075 mm from 10
Hz to 57 Hz
Acceleration: 1 g at 57 Hz to
150 Hz
Acc. to EN 600068-2-6
Max. shock:
15 g 11 ms
Acc. to EN 60068-2-27,
No malfunction
Max. shock:
15 g 11 ms
Acc. to EN 60068-2-27,
No malfunction
Contamination level
2
2
2
Overvoltage category
2
–
–
Tab. 4-5:
Ambient conditions
4.4
Standards
4.4.1
Standards used
The system components of the Operator Display correspond to the following
standards:
Standard
Description
EN 60 204-1
Safety of machinery - Electrical
equipment of machines
EN 61 000-6-4
Generic standards - Emission standard
(industrial environments)
EN 61 000-6-2
Generic standards – Noise immunity
(industrial environments)
EN 61 558-2-6
Transformer for 24 V power supply unit,
safe separation
EN 60 664-1
Overvoltage category II
EN 61 131-2
24 V output requirements
EN 61 131-2
24 V current supply requirements
ISO 13 850
Safety of machinery, E-STOP devices
EN 60 529
Degrees of protection (including housings
and installation compartments)
EN 60 068-2-6
Vibration test
EN 60 068-2-27
Shock test
EN 60 721-3-1 and
EN 60 721-3-3
Climatic class
Tab. 4-6:
Standards used
4.4.2
CE Marking
Declaration of Conformity
IndraControl VDP 16.3, VDP 40.3, VDP 60.3 Operator Display
13/57
Technical data
R911323862_Edition 07 Bosch Rexroth AG