cable grommet
cable wrap
cable
Fig.5-14:
Strain relief realized by a cable wrap
Using a blind grommet
Not used openings are to be covered with a blind grommet.
Fastening the cover
●
Check that the seal of the cover is not damaged.
●
Position the cover properly and fasten the screws with the corresponding
torque, see also
fig. 5-15 "Mounting torques" on page 35
5.2.3
Attachment to a Standardized VESA Bracket
Damage of cables due to wrong minimum
bending radius and use of unsuitable cable
material.
NOTICE
Do observe the minimum bending radius of the used cables.
Use suitable cable material (sufficient bending and torsional strength).
Damage of the mechanics caused by wrong
mounting torque.
NOTICE
If screws were removed because of maintenance works, they have to be fas‐
tened again with the corresponding mounting torque, see the following table.
Threads
Mounting torques
M2.5
0.4 Nm
M3
0.7 Nm
M4
1.4 Nm
M5
2.8 Nm
Fig.5-15:
Mounting torques
DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
Bosch Rexroth AG
35/81