B10d value auxiliary con‐
tact N/C contact ZBE-101
Electrics:
B10d = 10,000,000 (ac‐
cording to the manufactur‐
er)
Assumption: B10d = 2 x
B10
Exclusion of failure at <
6050 switching cycles
B10d value auxiliary con‐
tact N/O contact ZBE-102
Electrics:
B10d = 10,000,000 (ac‐
cording to the manufactur‐
er)
Assumption: B10d = 2 x
B10
Exclusion of failure at <
6050 switching cycles
Notes:
Not available for all VAM
variants.
Fig.4-11:
Technical data, EMERGENCY STOP
4.5
VAC 30.2 Connection Module for VEH 30.1, VEH 30.2 or VCH
08.1 Hand-Held Terminals
Connections
●
1 x Ethernet connection (RJ 45,
10/100 Base-T)
●
STOP button hand-held terminal
●
Enabling button, hand-held terminal
●
Voltage supply 24 V hand-held ter‐
minal (see IndraControl VEH 30.1,
VEH 30.2)
Material
Metal cover: V2A
Prescribed external protection:
2-A-fusible cut-out, time-lag
Fig.4-12:
Connection module for hand-held terminals VEH 30.1, VEH 30.2 or VCH
08.1
4.6
Ambient Conditions
Ambient conditions In operation
Transport
Storage
Max. ambient tem‐
perature
+5 ℃ to +45 ℃
-20 ℃ to +60 ℃
-20 ℃ to +60 ℃
Max. temperature
gradient
Temporal tempera‐
ture changes up to 3
K per minute
Temporal tempera‐
ture changes up to 3
K per minute
Temporal tempera‐
ture changes up to 3
K per minute
Bosch Rexroth AG
DOK-SUPPL*-VAM*11/41**-PR03-EN-P
Rexroth IndraControl VAM 11.1/41.1 Machine Control Panels
28/83
Technical Data