background image

  

 

NS

MS

LINK

PROFINET

 IO

 

IMpnio

 

3 609 929 B64/
2008-05

Summary of Contents for Rexroth IMpnio

Page 1: ...NS MS LINK PROFINET IO IMpnio 3 609 929 B64 2008 05 ...

Page 2: ...e data specified above only serve to describe the product No statements concerning a certain condition or suitability for a certain application can be derived from our information The information given does not release the user from the obligation of own judgment and verification It must be remembered that our products are subject to a natural process of wear and aging This document as well as the...

Page 3: ...ssible to all users at all times Always include the operating instructions when you pass the IMpnio interface module on to third parties Intended use The IMpnio interface module is a component in terms of the machine directive 98 37 EC and is not a ready for use machine The product is exclusively intended for being integrated in a machine or system or for being assembled with other components to f...

Page 4: ...eral safety instructions Only accessories and add on units that have been approved for use in Rexroth tightening systems may be used therein Non approved components may neither be added nor connected to the system The same applies to cables and lines which belong to the Rexroth tightening system Otherwise functional and system safety is jeopardized Observe the regulations for accident prevention a...

Page 5: ...oning make sure that all the plug connectors are installed correctly undamaged and that all screws are tightened During commissioning Let the product acclimate itself for several hours before commissioning otherwise water may condense in the housing Make sure that all electrical connections are either used or covered Commission the product only if it is installed completely During cleaning Cover a...

Page 6: ...es the connection or activity via Profinet Table 1 Pin Signal Description function 1 Transmit Profinet transmission cable 2 Transmit Profinet transmission cable 3 Receive Profinet reception cable 4 NC 5 NC 6 Receive Profinet reception cable 7 NC 8 NC 4 1 3 2 5 NS MS LINK Table 2 NS LED display Meaning Off No voltage not initialized or no connection to the IO controller Green Online RUN connection ...

Page 7: ...age or not initialized module in SETUP or NW_INIT status Green Module ready for operation module not in NW_INIT status Flashing green Flashes once Diagnostic events available Flashing green Flashes twice Network configuration with module identification running Red Exception error module in EXCEPTION status Flashing red Flashes once Configuration error Flashing red Flashes twice Error in the IP add...

Page 8: ... y Only qualified personnel see Personnel qualifications on page 17 are authorized to assemble the IMpnio interface module y Measures to prevent electrostatic discharge ESD protection must be undertaken to protect the module and system components during all assembly work CAUTION Risk of injuries when assembling under voltage If you do not switch off the power supply before assembling the IMpnio in...

Page 9: ...rface module 2 Insert the IMpnio interface module into the appropriate slot on the system component until it catches example in Fig 2 3 Tighten the torx screws on the front until the front panel is flush The circuit board is locked by turning the screw This lock is only fully functional once the interface has been properly tightened see Fig 3 Fig 2 Example Inserting the interface module Fig 3 Lock...

Page 10: ...ance free if used as intended Spare parts Please refer to the address directory under www boschrexroth com and in chapter 16 Service and sales on page 28 for the addresses of our foreign subsidiaries 10 Decommissioning For details about how to disassemble or replace your IMpnio interface module please refer to chapter 11 Disassembly and replacement on page 25 CAUTION Risk of damage to persons and ...

Page 11: ...relevant system components are not under voltage 2 Loosen the front torx screws The IMpnio interface module may only be removed once the lock has been completely released see Fig 4 3 Assemble a dummy panel if necessary Fig 4 Releasing the lock 1 Lock CAUTION Disconnecting the IMpnio interface module while under voltage Damage to the IMpnio interface module y Make sure the relevant system component...

Page 12: ... on errors are displayed in the tightening system e g in the BS350 The MS LED indicates the interface module status If you should not be able to remedy an occurring defect please contact one of the addresses that you can find under www boschrexroth com or in the address directory in chapter 16 Service and sales on page 28 Table 5 MS LED display Meaning Red Exception error module in EXCEPTION statu...

Page 13: ... 272 Dimensions width x height x depth 50 1 x 22 3 x 56 8 mm Weight 30 g Operating temperature range Designed for operation in System 350 components Storage temperature range 20 C to 70 C Permissible humidity for application 20 90 non condensing Permissible humidity for storage 20 95 Protection class in acc with EN 60529 IEC529 IP 20 NEMA 1 when installed Mounting orientation Any ...

Page 14: ...tailed description of the malfunction and conditions information on the name plate of the af fected product particularly the material and serial numbers telephone fax numbers and e mail ad dress where we can reach you if we have any questions Sales Bosch Rexroth AG Electric Drives and Controls Schraub und Einpress Systeme Fornsbacher Str 92 n D 71540 Murrhardt Postfach 1161 n D 71534 Murrhardt You...

Page 15: ...ice et distribution 41 Les indications données servent exclusivement à la description du produit Il ne peut être déduit de nos indications aucune déclaration quant aux propriétés précises ou à l adéquation du produit en vue d une application précise Ces indications ne dispensent pas l utilisateur d une appréciation et d une vérification personnelle Il convient de tenir compte du fait que nos produ...