Bosch Rexroth IMdev Manual Download Page 4

18

/84

Bosch Rexroth AG

IMdev  |    3 609 929 B41/2008-09

2 General safety instructions 

out by qualified technical personnel or an 
instructed person under the direction and 
supervision of qualified personnel.

Qualified personnel are those who can 
recognize possible hazards and institute the 
appropriate safety measures due to their 
professional training, knowledge, and 
experience, as well as their understanding of 
the relevant conditions pertaining to the work 
to be done. Qualified personnel must 
observe the rules relevant to the subject area.

Safety instructions in this document

In this manual, there are safety instructions 
before the steps whenever there is a danger 
of personal injury or damage to the 
equipment. The measures described to avoid 
these hazards must be observed.

Safety instructions are set out as follows:

Safety sign (warning triangle)

: draws 

attention to the risk

Signal word: 

identifies the degree of 

hazard 

Type of risk: 

identifies the type or source 

of the hazard

Consequences: 

describes what occurs 

when the safety instructions are not 
complied with

Precautions:

 states how the hazard can 

be avoided

The signal words have the following meaning:

Adhere to the following instructions

General safety instructions

Observe the regulations for accident 
prevention and environmental protection for 
the country where the product is used and at 
the workplace.
Exclusively use Rexroth products in good 
technical order and condition. 

Check the product for visible defects, for 
example damage to the printed card, 
components, housing, and plug connectors 
or missing screws.

Only use the product within the performance 
range provided in the technical data.

Persons who assemble, operate, 
disassemble or maintain Rexroth products 
must not consume any alcohol, drugs or 
pharmaceuticals that may affect their ability 
to respond.

The warranty only applies to the delivered 
configuration. 

SIGNAL WORD

Type of RISK!

Consequences

Precautions

This warning symbol cautions 
against dangers to your health. 
Observe all the safety instructions 
that follow this symbol to avoid 
possible injuries or death. 

This warning symbol cautions 
against dangers to your health 
caused by electrical voltage or 
currents. Observe all the safety 
instructions that follow this 
symbol to avoid possible injuries 
or death. 

CAUTION

CAUTION

 indicates a potentially 

hazardous situation which, if not avoided, 
could result in minor or moderate injury or 
damage to equipment.

IMdev.book  Seite 18  Donnerstag, 25. September 2008  1:40 13

Summary of Contents for Rexroth IMdev

Page 1: ...IMdev 3 609 929 B41 2008 09 IMdev book Seite 1 Donnerstag 25 September 2008 1 40 13 ...

Page 2: ...erve to describe the product No statements concerning a certain condition or suitability for a certain application can be derived from our information The information given does not release the user from the obligation of own judgment and verification It must be remembered that our products are subject to a natural process of wear and aging This document as well as the data specifications and othe...

Page 3: ... are accessible to all users at all times Always include the operating instructions when you pass the IMdev interface module on to third parties Intended use The IMdev interface module is a component in terms of the machine directive 98 37 EC partial machine The IMdev interface module is no ready for use machine in terms of the machine directive The product is exclusively intended for being integr...

Page 4: ...following meaning Adhere to the following instructions General safety instructions Observe the regulations for accident prevention and environmental protection for the country where the product is used and at the workplace Exclusively use Rexroth products in good technical order and condition Check the product for visible defects for example damage to the printed card components housing and plug c...

Page 5: ... may condense in the housing Make sure that all electrical connections are either used or covered Commission the product only if it is installed completely During cleaning Cover all openings with the appropriate protective equipment in order to prevent detergents from penetrating the system Never use solvents or aggressive detergents Only clean the product using a slightly damp lint free cloth Onl...

Page 6: ...onnections 1 3 2 4 NS MS 1 2 3 4 5 V CAN_H SHIELD CAN_L V 1 2 3 4 5 Table 1 Pin Signal Description Function Wire color 1 V Negative bus voltage Black 2 CAN_L CAN low Blue 3 Shield Protective ground Blank 4 CAN_H CAN high White 5 V Positive bus voltage Red Table 2 Type Supplier Plug part with bolt flange double row type TMSTBP 2 5 5 STF 5 08 ABGY AU article no 1853201 Phoenix Contact Plug part with...

Page 7: ...nection to master established data exchange has taken place Flashing green 1 Hz Network available but no connection to master established device waits for the master to set up a connection Red Error in the interface module critical connection error device has detected a network error double MAC ID or bus off Flashing red 1 Hz Communication has failed severe communication error Table 5 LED display ...

Page 8: ...tional once the interface has been properly tightened see Fig 4 CAUTION Risk of injuries and damage to property Assembly of the IMdev interface module requires basic mechanical and electrical knowledge y Only qualified personnel are authorized to assemble the IMdev interface module see Personnel qualifications on page 17 y Measures to prevent electrostatic discharge ESD protection must be undertak...

Page 9: ...ÊS SVENSKA FRANÇAIS 6 Assembly Fig 3 Example Slot A on the CS351 Compact System Fig 4 Lock effect 1 Lock 1M24V 1 17 9 1 24 C5C4 C2 C3 C1 16 8 X7E1 X3U1 X3U2 XDN1 X6C1 X3C1 XDV1 X3U4 X3U3 Reset B2 XDD1 X1S1 B1 A NOK OK FG Rexroth CS351 1 IMdev book Seite 23 Donnerstag 25 September 2008 1 40 13 ...

Page 10: ... COS Cyclical Bit strobe Explicit Idle running 9 Maintenance and repair Cleaning and care Maintenance The IMdev interface module is maintenance free if used as intended Spare parts The addresses for our national representatives can be found at www boschrexroth com and in the address directory in chapter 16 Service and sales on page 28 CAUTION Risk of injuries and damage to property Commissioning o...

Page 11: ...eed as follows to disassemble the IMdev interface module 1 Make sure the relevant system components are not under voltage 2 Loosen the front torx screws The IMdev interface module may only be removed once the lock has been completely released see Fig 5 3 Assemble a dummy panel if necessary Fig 5 Releasing the lock 1 Lock CAUTION Disconnecting the IMdev interface module while under voltage Damage t...

Page 12: ...you should not be able to remedy an occurring defect please contact one of the addresses that you can find under www boschrexroth com or in the address directory in chapter 16 Service and sales on page 28 Table 6 NS LED malfunction table LED display Meaning Red Error in the interface module critical connection error device has detected a network error double MAC ID or bus off Flashing red 1 Hz Com...

Page 13: ...h x height x depth 50 1 x 22 3 x 61 3 mm Weight 31 g Application temperature range Designed for operation in System 350 components Storage temperature range 20 C up to 70 C Permissible application humidity 20 90 non condensing Permissible storage humidity 20 95 Protection class in acc with EN 60529 IEC529 IP 20 NEMA 1 when installed Installation position Any IMdev book Seite 27 Donnerstag 25 Septe...

Reviews: