7.9 Sample applications
The following examples show some typical applications of the ID 40 system using
Profibus
.
7.9.1
“Manual workstation” application
Fig. 25:
Outfeed point
Workstation
Sample “manual workstation” application
The MDT should be read and written at a processing station. First, 32 bytes should
be read from the MDT address 0x0110, then 60 bytes should be written from the
MDT address 0x0100. The MDT status is also transmitted in order to allow any errors
in the MDT to be addressed.
The actual link state is read in an event-oriented manner to determine whether or
not a new MDT is in the link. The link state is contained in the event-oriented data
channel by default and is, e.g., provided in the input map in PLC systems.
The remaining data is exchanged with the MDT directly in the
CONNECTED
state. The
MDT then signs off with the commanded link state
RECONNECT
. The SLK switches to
the
CONNECTING
state to wait for the next MDT.
SLK preparation
The SLK switches to the link state
CONNECTING
with the command-oriented data
exchange.
No.
Command-oriented data
exchange
CMD
Data0 Data1 Data2 Data3 Data4 Data5 Data6
1
Make SLK ready to
receive (CONNECT)
0x06
0x00
0x03
0x00
0x01
0x00
0x01
0x01