74/84
Technical data
Bosch Rexroth AG
, MIT: ID 200, 3 842 540 399/2016-11
9.2 Technical data
General data
Component
Features
Antennas
max. 2
alternatively, 1 antenna and 1 trigger sensor
LEDs
Designation
Function
Status description
CH1
CH2
“Operation”
Status display of the antennas LED lights up
green
if a command is active
on the antenna.
LED lights up
yellow
for approx. 1 second if
a command has be executed successfully.
CH1
CH2
“Connect”
The connected antennas are
displayed
LED lights up
green
if an antenna is con-
nected to channel 1 or channel 2.
LED lights up
red
in the event of a configu-
ration error.
PWR/ERR
Status display of the ID
200/C-PDP
LED lights up
green
if the ID 200/C-PDP
is connected to an energy supply and the
interface is ready for operation.
LED lights up
red
in the event of a hardware
error.
Profibus
Status display of the bus
LED is off until the first communication via
the PROFIBUS.
LED lights up
green
if the slave is in data
exchange status.
LED lights up
red
if there is a bus error and
no data exchange is possible.
Diag
Status display of the data
transmission
LED lights up
green
if a direct PC connec-
tion is in place (see section 8.1.1).
LED lights up
yellow
if a command has been
sent directly via RS232 shell (see section 7.1.1).
Operating controls
Component
Features
Rotary switch
Address setting 00…7E, FF (hexadecimal)
BUS address (High Nibble): 0…7, F
BUS address (Low Nibble): 0…F
Electrical specifications
Features
Standard/value
Rated operating voltage
Ue
20…30 V DC, PEL V
Ripple
10 % at 30 V DC
Current consumption
2 A incl. antennas
Power consumption P0
2 W without antennas
Electrical isolation
Basic isolation according to DIN EN 50178,
Rated insulation voltage 50 Veff