32/84
Communication with ID 200/C-PDP
Bosch Rexroth AG
, MIT: ID 200, 3 842 540 399/2016-11
7.1.3
Write/read commands
The commands
SR
(single read words),
ER
(enhanced read words) and
SW
(single write words) only work with the mobile data carrier
MDT-H
.
Not
with the fixed code data carrier
MDT-L
!
Command Description
Parameter 1
Parameter 2
Parameter 3
Parameter 4
SR
Single Read
Read 32 bit
words
<RFIDChannel>
1
2
<WordAdr>
<WordNum>
Reply
<Status>
10
<RFIDChannel> <ByteCount>
<Data>
ER
Enhanced
Read
Permanently
read 32 bit
words
<RFIDChannel>
1
2
<WordAdr>
<WordNum>
Reply
<Status>
19
<RFIDChannel> <ByteCount>
<Data>
SW
Single Write
Write 32 bit
words in
<Data>
<RFIDChannel>
1
2
<WordAdr>
<WordNum>
<Data>
Reply
<Status>
40
<RFIDChannel>
SF
Single Read
Fixcode
Read 5-byte
fixed code
(MDT-L) or
8-byte UID
(MDT-H)
<RFIDChannel>
1
2
Reply
<Status>
01
<RFIDChannel> <ByteCount>
<Data>
EF
Enhanced
Read Fix-
code
Permanently
read 5-byte
fixed code
(MDT-L) or
8-byte UID
(MDT-H)
<RFIDChannel>
1
2
Reply
<Status>
1D
<RFIDChannel> <ByteCount>
<Data>
SX
Single Write
Fixcode
Write 5-byte
fixed code
(MDT-L)
<RFIDChannel>
1
2
<FixType>
02: locked
15: unlocked
<FixLength>
05
<Fixcode>
Reply
<Status>
1F
<RFIDChannel>