 CT100 /5A

READ 

:  Real time Value from Current Transducer [ Ampere ]

+

: Additional value to compensate real time value

-

: Subtract is Substraction value to compensate real
   time value

PRESS Button                  to select/move for edit Parameter

Enter the Data Number with Keypad 

①②③④⑤⑥⑦⑧⑨⓪

 and comfirm data with press                  as confirmation

Press   

         for escape to main menu setting

 A.P.R

APR SPEED

: To Define Speed of Propotional Valve as Accelaration
   [ Load ] or Deceleration [ Unload ]

MT. Unload /Step

: To Define percentage as output in Manual Operation 
    in Proportional Valve
   Example : Enter Value [1%] will be Output in Voltage 

 

n

r

e

g

g

ir

T

 

h

t

c

i

w

S

 l

a

u

n

a

M

 r

o

t

c

e

l

e

S

 

e

li

h

W

  

r

e

t

e

m

a

r

a

P

 t

i

d

e

 r

o

e

v

o

m

/

t

c

e

l

e

s

 

o

  

  

  

  

  

  

  

  

 

n

o

t

t

u

B

 

S

S

E

R

P

   Unload 

Enter the Data Number with Keypad 

①②③④⑤⑥⑦⑧⑨ ⓪

 and comfirm data with press                  as confirmation

Press   

         for escape to main menu setting

 Hour Run

Total Hour Run

: Start operate from the L point 

Service I

: Prompt View to Service Power Pack Unit
   Example : 1000 Hours to Exchange Filter

PRESS Button                  to select/move for edit Parameter

Enter the Data Number with Keypad 

①②③④⑤⑥⑦⑧⑨ ⓪

 and comfirm data with press                  as confirmation

Press   

         for escape to main menu setting

 BRH Code

REXROTH BRH CODE :

 This Manufacturer Machine Code 

    To Verified  Client To Claim Registration & Warranty

  Noted : 

Motor  Rating 1.5KW with Full Load Current at [ 3.4ampere]
Motor  Rating 30KW with Full Load Current at [ 54ampere]
Motor  Rating 37KW with Full Load Current at [ 67ampere]

Default ACU Series Current Transducer will be at 100A for Measurement

The Scale of 30KW & 37KW Motor Rating

Exmple : 5milisec per step to define as Accelaration Speed

Output will Convertion as milisecond to Voltage
ramp speed. thus pressure hydraulic cylinder

shall effective direclty with the setting APR speed

Summary of Contents for Rexroth ACU Series

Page 1: ...ELCB 20mA in the power supply to be connected to the power terminal The fuse shuold be positioned between the switch or the breaker and the instruments and be attached to the L side of the power terminal Fuse Rating Type 250Vac 3A 5A Medium lagged or lagged type IEC127 requirements In the wiring operation make sure to fsten terminal connections Power voltage and frequency must be within their rate...

Page 2: ...ter the Data Number with Keypad and comfirm data with press as confirmation Press for escape to main menu setting PASSWORD NEW PASSWORD Adminstartor Password Register REGISTERD PASSWORD As Display Password Updated Noted If Password are forgotten Enter 1125 to clear the machine password register PRESS Button to select move for edit Parameter Enter the Data Number with Keypad d r o w s s a P t c e r...

Page 3: ...mfirm data with press as confirmation Press for escape to main menu setting Hour Run Total Hour Run Start operate from the L point Service I Prompt View to Service Power Pack Unit Example 1000 Hours to Exchange Filter PRESS Button to select move for edit Parameter Enter the Data Number with Keypad and comfirm data with press as confirmation Press for escape to main menu setting BRH Code REXROTH BR...

Page 4: ... 2 CONNECT 1 CONNECT 2 Double DC Coil R900561282 4WE6 G6X EG24N9K4 Single DC Coil R900561274 4WE6 D6X EG24N9K4 Single AC220V Coil R900909559 4WE6 D6X EW230N9K4 APR R901325099 KBVSFIBA FV VALVE R901263782 VT SSPA1 150 1X V0 0 24 K24 AMPLIFIER PLUG R901241656 VT SPPA1 1X M12 V00 CABLE SET Rexroth Hydraulic Part Number Ref DIRECTIONAL VALVE ACU Series LCD Digital Controller Parameter Setting Rexroth ...

Page 5: ...ternal Termination Diagram to Douuble Solenoid Coil DC24V VCC 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 L1 L2 L3 N APR DC24V DINPLUG INCOMING SUPPLY AC415V 3P N E CURRENT TRANSDUCER 100 5A E IN IN UB GND CONNECT UB CONNECT GND CONNECT IN CONNECT IN ACU Series Internal Termination Diagram to 1 Solenoid Coil AC220V ACU Series LCD Digital Controller 4 in 1 ACU Series Control Wiring Termination 1 2 CONNE...

Reviews: