![Bosch Rexroth A6VM series 71 Manual Download Page 4](http://html.mh-extra.com/html/bosch/rexroth-a6vm-series-71/rexroth-a6vm-series-71_manual_43003004.webp)
Bosch Rexroth Corp.
, RE-A 91610/12.2015
4
A6VM series 71 | Axial piston variable motor
Type code
3)
Only possible in conjunction with HP, EP and HA control. Note the
restrictions described on page 65.
4)
State ordering code for counterbalance valve separately in accor-
dance with data sheet 95522 for BVD or 95525 for BVE. Note the
restrictions described on page 65.
5)
Not for EZ7, EZ8 and HZ7.
6)
State ordering code for sensor separately in accordance with data
sheet 95132 for DSM or 95133 for DSA and note the requirements
relating to the electronics.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
A6V
M
0
0
/
71
A
W
V
0
–
Drive shaft
060
085
115
150
170
215
17 Splined shaft
ANSI B92.1a
1 1/4 in 14T 12/24 DP
●
‒
‒
‒
‒
‒
S7
1 1/2 in 17T 12/24 DP
‒
●
‒
‒
‒
S9
1 3/4 in 13T 8/16 DP
‒
‒
●
●
‒
‒
T1
2 in 15T 8/16 DP
‒
‒
‒
○
●
●
T2
Port plate for working ports
060
085
115
150
170
215
18 SAE working ports A and B at rear
●
●
●
●
●
●
1
SAE working ports A and B at side, opposite
●
●
●
●
●
●
2
Port plate with 1-stage pressure limitation
valves for mounting a counterbalance valve
3)
BVD20
●
●
●
‒
‒
‒
7
BVD25, BVE25
‒
‒
●
●
●
●
8
Valve (see pages 63 to 68)
060
085
115
150
170
215
19 Without valve
●
●
●
●
●
●
0
With counterbalance valve BVD/BVE mounted
4)
●
●
●
●
●
●
W
With flushing and boost pressure valve, mounted
Flushing on both sides
Flushing flow at:
Δp
=
p
ND
‒
p
G
= 365 psi (25 bar) and
ν
= 60 SUS (10 mm
2
/s)
(p
ND
= low pressure,
p
G
= case pressure)
Only possible with port plates 1 and 2
Flushing flow
q
v
[gpm (l/min)]
0.9
(3.5)
●
●
●
‒
‒
‒
A
1.3
(5)
●
●
●
‒
‒
‒
B
2.1
(8)
●
●
●
●
●
●
C
2.6
(10)
●
●
●
●
●
●
D
3.7
(14)
●
●
●
‒
‒
‒
F
4.0
(15)
‒
‒
●
5)
●
●
●
G
4.8
(18)
‒
‒
●
5)
●
●
●
I
5.5
(21)
‒
‒
●
5)
●
●
●
J
7.1
(27)
‒
‒
●
5)
●
●
●
K
8.2
(31)
‒
‒
●
5)
●
●
●
L
9.7
(37)
‒
‒
‒
●
●
●
M
Speed sensor (see page 69)
060
085
115
150
170
215
20 Without speed sensor
●
●
●
●
●
●
0
Prepared for speed sensor DSM/DSA
●
●
●
●
●
●
U
With speed sensor DSM/DSA mounted
6)
●
●
●
●
●
●
V
Standard / special version
21 Standard version
0
Standard version with installation variants, e. g. T ports against standard open and closed
Y
Special version
S
●
= Available
○
= On request
‒
= Not available
Notes
▶ Note the project planning notes on page 74.
▶ When ordering, please provide the relevant technical
data additionally to the type code