46/64 Installation
Bosch Rexroth AG
, Series 10 A10VG, RE 92750-01-B/06.2018
7.5 Performing flushing cycle
In order to remove foreign particles from the system, Bosch Rexroth recommends
a flushing cycle for the entire system before initial commissioning. To avoid internal
contamination, do not include the axial piston unit in the flushing cycle.
Use an additional flushing unit to perform the flushing cycle. Follow the
instructions of the flushing unit's manufacturer for the exact procedure during the
flushing cycle.