background image

 

17553v1.0  

3.2 Telnet Configuration 

3.2.1 Connecting to the UDS 

The UDSs can be connected outside of the 

DeviceInstaller

 by using Windows Telnet. To do this, connect 

using the unit’s assigned IP Address and a port number of 9999. For example: use the command 

TELNET 

192.168.101.52 9999

 at the command prompt.  

Notes 

1.  In the following example, text enclosed in a

 gray box

 represents the screen display of whatever 

application is hosting the Telnet session. 

2. 

Bold

 text in the 

gray box

 represent example values. 

3.  This is an example configuration with no gateway. If a gateway is required on a specific network, it 

should be configured on the relevant gateway. 

When Telnet has connected to the UDS, the following (or similar) is displayed: 

*** Lantronix Universal Device Server *** 
Serial Number 

5423446

  MAC address 

00:20:4A:54:5B:96

 

Software Version V04.2 (000908) 
Press Enter to go into Setup Mode 

Press 

Enter

Hardware: Ethernet Autodetect 
IP addr 

192.168.31.202

, no gateway set,netmask 

255.255.255.000

 

 
***************** Security ***************** 
Telnet setup is      enabled 
TFTP download is     enabled 
Port 77FEh is        enabled 
Web Server is        enabled 
Enhanced password is disabled 
 
***************** Channel 1 ***************** 
Baudrate 9600, I/F Mode 4C, Flow 00 
Port 10001 
Datagram Type 01 
Pack Cntrl:   00 
Remote IP Adr: 

192.168.004.243

, Port 

00000

 

 
 
 
Change Setup  : 0 Server configuration 
                1 Channel 1 configuration 
                6 Security 
                7 Factory defaults 
                8 Exit without save 
                9 Save and exit                Your choice ? 

3.2.2 UDS to PC Configuration 

This section describes the configuration of the UDS for network operation. 

Configuration 

From the main menu (displayed above) type

 0 

(for the option 

Server Configuration

) and press 

Enter

 

IP Address : (000) 

192.

(000) 

168.

(000) 

101.

(000) 

27<enter> 

 

Set Gateway IP Address (Y) 

Y<enter> 

 

Gateway IP addr (000) 

192.

(000) 

168.

(000) 

101.

(000) 

254<enter> 

 

Netmask: Number of Bits for Host Part (0=default) (00) 

8<enter> 

 

Change telnet config password (N) 

N<enter> 

Summary of Contents for Readykey X UDS-10

Page 1: ...17553v1 0 Jan 08 UDS 10 UDS 1100 Serial Tunnel on CNC Setup Guide ...

Page 2: ...tion 4 3 1 DeviceInstaller Configuration 4 3 2 Telnet Configuration 7 3 2 1 Connecting to the UDS 7 3 2 2 UDS to PC Configuration 7 3 2 3 PC to Door Controller Configuration 9 3 3 Testing Network Connectivity 10 4 Configuring the Door Controller 11 5 Configuring the Channel 11 ...

Page 3: ...into packets and transports them over the network Note If replacing pIPer Serial Ethernet units the pIPers at both ends must be replaced with UDS devices 2 Installation UDS 1 is connected to a serial port on the PC CNC A standard 9 way to 25 way serial cable can be used UDS 2 is connected to the serial port on the first door controller The serial lead can be supplied part no 12090 Alternatively a ...

Page 4: ...guration Notes 1 The procedure carried out in this section has to be performed before Telnet Configuration see Section 3 2 can be carried out 2 Make a note of the MAC Address of the UDS printed on the underside of the UDS or on the cover above the IP unit of the K2200IP 3 Consult your IT department to determine the IP Address and the PC Network Class for the UDS Procedure 1 Run the DeviceInstaller...

Page 5: ...Search the network for devices and the Search Network window is displayed 7 Select the PC Network Class 8 Select the Start Search button and any UDS devices on the network will be displayed 9 Select the Save button and the DeviceInstaller window is redisplayed with a list of all UDS devices detected ...

Page 6: ...evice 11 Select Tools Device Manager and the Device Management window is displayed 12 Select Telnet to Device and a Telnet session will then start The DeviceInstaller part of the UDS configuration is complete the next part is using Telnet ...

Page 7: ... Software Version V04 2 000908 Press Enter to go into Setup Mode Press Enter Hardware Ethernet Autodetect IP addr 192 168 31 202 no gateway set netmask 255 255 255 000 Security Telnet setup is enabled TFTP download is enabled Port 77FEh is enabled Web Server is enabled Enhanced password is disabled Channel 1 Baudrate 9600 I F Mode 4C Flow 00 Port 10001 Datagram Type 01 Pack Cntrl 00 Remote IP Adr ...

Page 8: ...r other examples Mask Bits 255 0 0 0 24 255 255 0 0 16 255 255 240 0 12 255 255 248 0 11 255 255 254 0 9 255 255 255 0 8 255 255 255 128 7 255 255 255 192 6 255 255 255 224 5 255 255 255 240 4 255 255 255 248 3 Change telnet config password Press the N key and press Enter The basic parameters menu will be displayed basic parameters Hardware Ethernet Autodetect IP addr 192 168 004 241 no gateway se...

Page 9: ...efault value I F Mode Press Enter to accept the default value Flow Press Enter to accept the default value Port No Enter the port number and press Enter ConnectMode Enter the connect mode for the administration software and press Enter Datagram Type Enter the value 01 and press Enter Remote IP Address Enter IP address of the PC and press Enter Remote Port Press Enter to accept the default value Pa...

Page 10: ...ing Device and the Ping Device window is displayed 3 Enter the IP Address of the unit to be pinged and select the Ping Device Successful pinging will be indicated by text similar to that displayed Note Do not attempt to set up the door controller within application software until you have established that the PC can see the UDS over the network ...

Page 11: ...1 System Type 2 2 Baud Rate to 9600 3 Connect Modem set to N To set these parameters see the documentation supplied with the door controller 5 Configuring the Channel The channel can be configured using Readykey for Windows or Readykey X To set up the channel see the documentation and helpfiles supplied with the application software ...

Page 12: ...www boschsecurity us ...

Reviews: