Environmental temperature (°C)
Load
(W
att)
5
10
15
20
0
25
30
Fig. 17-8:
Max. load by 10 axes (5 NY4130 drive modules, control frequency =
32 kHz) and all digital outputs at 1 A load vs. environmental temper‐
ature
17.5.8
Forced cooled systems, NY4140
The NYCe 4000 system can be installed with a standard fan unit with 3 fans
each producing an airflow of 11.3 m
3
/hr. When five NY4140 drive modules
are used in the NY4053 system housing, you can build the maximum
configuration with 5 axes.
fig. 17-9 "Max. motor current for 5 axes (5 NY4140
drive modules, PWM frequency = 32 kHz) and all digital outputs at 1 A load
/hr) installed vs. environmental temperature" on
shows the situation where all 5 motors ask continuously the same
motor current, PWM frequency is 32 kHz, and all 10 digital outputs drive a
load of 1 A continuously. Under these conditions the maximum motor current
is 7 A rms at an environmental temperature of up to 55 °C.
70
20
30
40
10
0
50
60
Environmental temperature (°C)
Motor
current
(A. rms)
2
4
6
8
0
Fig. 17-9:
Max. motor current for 5 axes (5 NY4140 drive modules, PWM fre‐
quency = 32 kHz) and all digital outputs at 1 A load with 3 fans (air‐
flow 11.3 m
3
/hr) installed vs. environmental temperature
17.5.9
Convection cooled systems, NY4140
When five NY4140 drive modules are used in the NY4053 system housing,
you can build the maximum configuration with 5 axes.
motor current for 5 axes (5 NY4140 drive modules) and all digital outputs at
1A load vs. environmental temperature" on page 224
NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual
223/233
Environmental Conditions
R911337671_Edition 18 Bosch Rexroth AG