Bosch Security Systems B.V.
Configuration manual
2020-09 | V1.20 | PRAESENSA 1.20
5.7.5
Multifunction power supply
On the Action definitions page of the Multifunction power supply the Control inputs and
control outputs could be defined.
1.
Below
the Action definitions configuration page,
click
Multifunction power supply (Mps):
–
A screen appears with on overview of the connected Mps(s).
2.
Select and click
the name of the Mps to be configured.
–
A row called Control inputs appears.
–
A row called Control outputs appears.
3.
Click
the + of the Control inputs row:
–
A screen appears listed the eight Control Inputs each with the following items:
Item
Value
Description
Name
[#0n]
Static text
Shows
the name of control input which is
entered
in
section
Multifunction power supply, page 53
Function
Static text
Shows
the name of the function which is
selected
in
section
Multifunction power supply, page 53 > control
inputs chapter
Operation
Selection
Select
the operation of the function which is
selected
in section
Multifunction power supply, page 53. See
also
Assigning an operation, page 84.
Call definition
Selection
Select
the call definition which is created in section
Depending of the selected Function, different parameters could be selected, entered,
added/removed. See
Assigning a function, page 85 for descriptions.
Submit
Button
Click
the Submit button to store the settings: Notice
that you always have to Save the configuration. See
Save configuration, page 102
Configure control inputs
Assigning a function, page 85 for functions and Assigning an operation, page 84 for
operations available for the Mps.
Each of the eight control inputs listed can be individual configured. To do so:
1.
Select
the operation (and Call definition) from the dropdown list.
2.
Select
,
enter
and/or
add/remove
the parameters belonging to the selected function.
3.
Click
the Submit button to store the settings. See also
Configure control outputs
1.
Click
the + of the Control outputs row:
–
A screen appears listed the eight control outputs.
2.
With the exception of Zone activity, the Name and the function of the control outputs are
static and can only be changed in the section
Multifunction power supply, page 53.
–
Notice that the Zone activity function requires: Priority range selection (Higher and
lower priority) between 0 and 255 and zone selection.
–
Notice that if the function text is called Disabled, the control output is disabled in
the section