569217 | REV. D | 09.08.2016
Installation and Operating Instructions
|
Power Max
Level 2 Charging Station |
7
|
en
3.3
Specifications
Model
EL-51245-XXXXX EL-51253-XXXXX
EL-51254-XXXXX
Power Input
Input Rating
208-240 Vac, 16 A
208-240 Vac, 30 A
208-240 Vac, 30 A, 60 Hz
Connections & Wiring
L1, L2, and Ground, hardwired w/ terminal block
Standby Power
< 5 W
Power Output
Output Rating
208-240 Vac, 16 A
208-240 Vac, 30 A
208-240 Vac, 30 A
Cold-Load Pickup
Randomized delay before charge resume after power failure
Protection
Internal Residual
Current Detection
20 mA CCID per UL 2231
Upstream Breaker
2-pole 20 A
breaker on dedi-
cated circuit,
non-GFCI type
2-pole 40 A breaker on dedicated circuit,
non-GFCI type
Output Protection
Power output is terminated upon detection of charging connector
plug-out
Electrical Protection
Over current, short circuit, over voltage, under voltage, ground
fault, surge protection, over temperature
User Interface &
Control
Status Indicators
Standby (solid green), charging (flashing green), fault (solid red),
warning (flashing red)
Buttons/Switches
ON/OFF switch, stop button
Environmental
Operating
Temperature
-22
o
F to +122
o
F (-30
o
C to +50
o
C)
Humidity
95% relative humidity, non-condensing
Mechanical
Charging Cable Length 12/18/25-ft cable
18-ft cable
25-ft cable
Ingress Protection
Type 3R
Mounting Type
Wall-Mount
Dimension (W x H x D)
13.8 x 15.7 x 5.0 inch (350 x 400 x 126 mm), excluding charging
cable and support bracket
Net Weight
15.4 lb (7 kg)
Regulation
Certificate
UL, cUL
Charging Interface
SAE J1772 compliant charging plug