12.10 Gas leak test
Use soapy water to test for leaks
1.
Use a soft brush dipped in soapy water to coat the
connecting section of the gas pipeline.
2.
Open the gas valve and carefully observe whether
bubbles form.
If bubbles form, close the gas valve immediately.
3.
Adjust the leaking connecting section.
4.
Repeat the above steps until there are no air
bubbles on the connecting section.
12.11 Connecting the appliance to the
electricity supply
1.
Insert the mains plug of the appliance's power cable
in a socket nearby.
2.
Check the mains plug is inserted properly.
a
The appliance is now ready for use.
Power cable
The power cable is fixed on the right of the appliance.
Make sure it is safety and grounded when you use it.
The socket should be away from the gas and air inlet,
and it is recommended to be fixed on the right side of
the appliance.
≈800mm
≈100mm