Bosch Security Systems | 2003-09 | 9922 141 50502en
Plena Message Manager
| Installation and Operating Manual |
en
| 23
5.5 Controls
Trigger inputs (Screw)
Activation
contact closure
Supervision
on trigger inputs 1-6, selectable
Supervision method
loop resistance check
Control outputs (Screw)
Message active relay
100 V, 2 A (voltage free, SPDT)
Fault relay
100 V, 2 A (voltage free, SPDT)
RS232 (9-pin D-sub)
PC to LBB1965/00
115 kb/s, N, 8, 1, 0 (upload)
LBB1965/00 to LBB1925/10
19.2 kb/s, N, 8, 1, 0 (zone control)
5.6 Environmental conditions
Operating temperature range
-10 to +55 °C
Storage temperature range
-40 to +70 °C
Relative humidity
< 95%
5.7 General
EMC emission
acc. to EN 55103-1
EMC immunity
acc. to EN 55103-2
Dimensions
56 x 430 x 270 mm (19
”
wide, 1U high, with feet)
Weight approx.
3
kg
19
”
mounting brackets
included
Technical data