12
Request change-over injectors from our customer service
deparment (refer injector chart below for sizes).
Natural Gas
Universal LPG
Burner
Hourly Gas
Consumption
(MJ)
Injector
mark
Hourly Gas
Consumption
(MJ)
Injector
mark
(mm)
Auxiliary
3,60
90
3,50
50
Semi-rapid
6,50
118
6,00
67
Rapid
10,80
155
10,00
85
Triple flame
16,00
182
13,50
100
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Changing the nozzles
of the burners on the
cooktop
- Remove the pan supports, burner covers and
diffusers.Fig. 7.
Fig. 7
- Change the nozzles using the spanner provided by our
Service Centre (code 340847, for double and triple flame
burners code 340808), taking special care to ensure that
the nozzle does not fall when it is removed from the
burner or when fitted. Fig. 8.
Ensure that it is completely tightened in order to
guarantee the seal.
Fig. 8