PAVIRO End‑of‑line supervision module

PVA‑1WEOL

en

User manual

Summary of Contents for PAVIRO PVA-1WEOL

Page 1: ...PAVIRO End of line supervision module PVA 1WEOL en User manual ...

Page 2: ......

Page 3: ...on module Table of contents en 3 Bosch Security Systems B V 2019 01 V2 F01U350870 Table of contents 1 Short information 4 2 Installation 5 3 Technical data 10 4 Standards and compliancy 13 5 Compatibility with older EOL modules 14 ...

Page 4: ...ntinuous business music is requested In combination with the EOL master integrated in every Controller and Router of the PAVIRO system the loudspeaker line can be monitored for short and open circuits The status LED on the module can be used to check the installation For more information refer to the user documentation for the IRIS Net Controller or Router Parts included Quantity Component 1 End o...

Page 5: ...d of line supervision module you have to Mount the module Set the module address Connect the module to the speaker line Connect the module to earth or ground Check the installation 2 4 3 2 1 Figure 2 1 End of line supervision module Item Description 1 DIP switch S1 2 DIP switch S2 3 Status LED 4 Connector Speaker line Speaker line Earth ...

Page 6: ...ress must be set with the DIP switches S2 and S1 see previous figure and following table The module address allows for identification of the affected loudspeaker line in case an error occurred such as an open circuit 6 5 4 3 2 1 Module address DIP switch S2 DIP switch S1 4 3 2 1 4 3 2 1 OFF OFF OFF OFF OFF OFF 0 not connected OFF OFF OFF OFF OFF ON 1 OFF OFF OFF OFF ON OFF 2 OFF OFF OFF OFF ON ON ...

Page 7: ...ch S1 4 3 2 1 4 3 2 1 OFF OFF ON OFF OFF OFF 8 OFF OFF ON OFF OFF ON 9 OFF OFF ON OFF ON OFF 10 OFF OFF ON OFF ON ON 11 OFF OFF ON ON OFF OFF 12 OFF OFF ON ON OFF ON 13 OFF OFF ON ON ON OFF 14 OFF OFF ON ON ON ON 15 OFF ON OFF OFF OFF OFF 16 OFF ON OFF OFF OFF ON 17 ON ON ON ON OFF OFF 60 OFF Reserved ON OFF To activate the status LED for five minutes ON ...

Page 8: ...h zone topology each controller router or amplifier Connect the module to the speaker line Connect the speaker line wires to the plus and minus contacts of the connector Make sure the capacitance limit of parallel connected speaker lines is not exceeded as described in Technical data page 10 Connect the module to earth or ground Use the earth contact on the connector to connect the module to earth...

Page 9: ...line and earth 1 Activate the LED for five minutes by setting switch 4 on DIP switch S2 to OFF and back to ON 2 Use the following table to check the status of the installation Status LED Description OFF No voltage supply for example pilot tone is deactivated Slow flashing 2 Hz Correct power supply pilot tone is on the speaker line Module is ready Rapid flashing 10 Hz every 40 seconds A valid comma...

Page 10: ... version 1 3 in combination with PVA 4CR12 or PVA 4R24 hardware version 02 00 For information on previous versions see Compatibility with older EOL modules page 14 Electrical Power supply 18 22 kHz 8 Veff 20 mW Wire limits Minimum RG 3 MΩ Maximum Cg 2500 nF Number of modules 60 Mechanical Product dimensions Height x Width x Depth 15 mm x 78 mm x 60 mm Net weight 30 g Environmental Operating temper...

Page 11: ...n parallel with other EOL modules on other speaker lines The capacitance of parallel connected speaker lines must be summed to determine the total capacitance Cg that one EOL Master can drive Make sure the worst case situation does not exceed the maximum allowed capacitance A capacitance calculator to check if the capacitance is in the safe zone and an additional application note can be downloaded...

Page 12: ...AVIRO End of line supervision module 2019 01 V2 F01U350870 Bosch Security Systems B V Figure 3 1 Circuit diagram RG and CG are caused by the loudspeaker installation e g wire type length Figure 3 2 Wiring diagram CG C1 C2 C3 ...

Page 13: ... rules Operation is subject to the following two conditions This device may not cause harmful interference and This device must accept any interference received including interference that may cause undesired operation ICES 003 This class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada EN 54 16 ISO7240 16 End of li...

Page 14: ...nd software versions can be used in the same system however the lowest Cg must be taken as the maximum Cg for the system The limits in this section are valid for PVA 1WEOL in combination with PVA 4CR12 or PVA 4R24 hardware version 02 00 PVA 1WEOL HW 1 1 FW 1 1 Minimum RG 1 5 MΩ Maximum Cg 200 nF Number of modules 60 PVA 1WEOL HW 1 1 FW 1 2 Minimum RG 1 5 MΩ Maximum Cg 800 nF Number of modules 58 ...

Page 15: ...PAVIRO End of line supervision module Compatibility with older EOL modules 15 Bosch Security Systems B V 2019 01 V2 F01U350870 ...

Page 16: ...16 Compatibility with older EOL modules PAVIRO End of line supervision module 2019 01 V2 F01U350870 Bosch Security Systems B V ...

Page 17: ......

Page 18: ...Bosch Security Systems B V Torenallee 49 5617 BA Eindhoven Netherlands www boschsecurity com Bosch Security Systems B V 2019 ...

Reviews: