IP Camera 200 Series
Installation | en
19
Bosch Security Systems
Installation and Operation Manual
AR18-10-B012 | v1.5 | 2011.01
3.5
I/O connector
Figure 3.4
I/O connector pins
–
Cut back 5 mm (0.2 in) of insulation.
–
Relay output switching capability: Max. voltage 24 VAC or
24 VDC. Max. 1 A continuous, 12 VA.
–
Relay in: Short or +5 VDC activation.
–
Alarm input configurable as active low or active high.
Function
Wire
Color
Relay out
AWG20
Grey
AWG20
Red
Alarm input
AWG30
Orange
AWG30
Brown
5 mm
(0.2 in)
In: AWG30
Out: AWG20