6
Robert Bosch Hausgeräte GmbH
Cleaning the bowl and tools
The bowl and tools are dishwasher-safe.
Do not wedge plastic parts in the dishwasher,
as they could be permanently deformed during
the washing process!
Cleaning the blender
^ííÉåíáçå>
aç=klq=ìëÉ=~Äê~ëáîÉ=ÅäÉ~åáåÖ=~ÖÉåíëK=
aç åçí ÅäÉ~å=íÜÉ=ÄäÉåÇÉê=áå=íÜÉ=ÇáëÜï~ëÜÉêK=
aç åçí=äÉ~îÉ=íÜÉ=ÄäÉåÇÉê=áå=ï~íÉêK
It is recommended to clean the blender
immediately after use. This will prevent
residue from drying on and attacking the
plastic (e. g. by essential oils in herbs).
Clean the blender cover in the dishwasher.
Clean the blender under running water.
Tip:
Pour water with a little washing-up
liquid into the attached blender (approx.
half full). Switch on the blender for several
seconds (
setting M
). Pour out the water
and rinse out the blender with clear water.
Troubleshooting
The swivel arm must be engaged in every
operating position.
First try to eliminate the problem with the aid
of the information in the following table.
If the fault cannot be eliminated, please contact
customer service.
Application examples
Whipped cream
200 g–1,500 g
Whip cream with the whisk for 1½
to 4 minutes at setting 4 (depending on the
quantity and properties of the cream).
Egg white
2 to 12 egg whites
Beat egg white with the whisk for 2
to 6 minutes at setting 4.
Sponge mixture
_~ëáÅ=êÉÅáéÉ
3 eggs
3–4 tbs. hot water
150 g sugar
1 packet of vanilla sugar
150 g flour
en
oáëâ=çÑ=áåàìêó=Ñêçã=ëÜ~êé=Ää~ÇÉë
aç=åçí=íçìÅÜ=ÄäÉåÇÉê=Ää~ÇÉë=ïáíÜ=
Ä~êÉ=Ü~åÇëK=`äÉ~å=íÜÉã=ïáíÜ=
~ ÄêìëÜK
oáëâ=çÑ=áåàìêó
_ÉÑçêÉ=Éäáãáå~íáåÖ=~=Ñ~ìäíI=éìää=çìí=
íÜÉ=ã~áåë=éäìÖK
Fault
Remedial action
Tool does not
stop in the tool
change position.
Switch appliance to 0/off
and then back to the
required setting.
Appliance does
not start/restart
lock-out is
active.
Check the power supply.
Check the mains plug.
Switch appliance to 0/off
and then back to the
required setting.
Check swivel arm. Correct
position? Engaged?
Appliance does
not start/restart
lock-out is
active.
Screw on blender or bowl
as far as possible.
Attach the blender cover
and screw on as far as
possible.
Attach drive cover
to unused drives.
Blender does
not start working
or stops during
use, the drive
is “humming”.
The blender blade is blocked
by one of the ingredients.
Switch off the appliance
and pull out the mains plug.
Detach the blender and
remove the obstruction.
Re-attach the blender.
Switch on the appliance.
Appliance
switches off
during use.
The overload protection
feature has been activated.
Switch off the appliance
and pull out the mains
plug.
Leave the appliance to
cool down for approx.
15 minutes in order to
deactivate the overload
protection.
Switch on the appliance
again. If the motor still
does not start, leave the
appliance to cool down
for a longer period (at least
1 hour).
Summary of Contents for MUM8-AU
Page 1: ...en Operating instructions MUM8 AU ...
Page 9: ...9000657580 04 2011 en Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany ...
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......