9.12
Motor cooling
9.12.1
Natural convection
Rexroth motors in standard design are self-cooling. The heat dissipation is
realized via natural radiation to the ambient air and by heat conduction to the
machine structure. The nominal data are achieved at ambient temperatures
of up to 40 °C. Sufficient heat radiation must be ensured by the installation
situation. Unhindered vertical convection has to be ensured by a sufficient
distance of 100 mm to adjacent components on the side surfaces.
Contamination of the motors reduces heat dissipation. Pay atten‐
tion to cleanliness!
9.12.2
Fan units
Fan units are available for certain motor types. The performance data given
in the technical data are marked with the index "S" for "surface". Descriptions
of the technical data of the available fan units can be found at
"Fan units for MSK motors" on page 180
.
Cooling takes place via air streams which are guided over the surface of the
motor by air baffles. The fan is designed to use clean air from its surround‐
ings to cool the motor.
The use of the fan under the following conditions is expressly not suitable:
●
Delivery of air which contains abrasive particles
●
Delivery of air which has a strongly corroding effect, e.g., salt mist
●
Delivery of air which contains a high dust load, e.g., extraction of saw
dust
●
Conveying of flammable gases/particles
●
Use of the fan units as safety-related components or for the assumption
of safety-relevant functions
In order for the required air volume to be converted by the fan unit, a mini‐
mum distance must be maintained between the fan grille and the machine for
the air to be sucked in or blown out. The distance results from the motor
structure.
80 mm
80mm
1
2
1
2
3
3
①
Machine
②
Air outlet space
①
Air suction area
Fig. 9-13:
Fan units installation area, minimum distance
Consider the minimum distance of the air supply ③ when designing the ma‐
chine.
Bosch Rexroth AG
DOK-MOTOR*-MSK********-PR12-EN-P
226/279
Synchronous Servomotors MSK
Operating conditions and application notes
Summary of Contents for MSK030B-0900-NN
Page 1: ...Synchronous Servomotors MSK Project planning manual R911296289 Edition 12 ...
Page 12: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 10 279 Synchronous Servomotors MSK ...
Page 24: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 22 279 Synchronous Servomotors MSK ...
Page 160: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 158 279 Synchronous Servomotors MSK ...
Page 180: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 178 279 Synchronous Servomotors MSK ...
Page 238: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 236 279 Synchronous Servomotors MSK ...
Page 242: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 240 279 Synchronous Servomotors MSK ...
Page 248: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 246 279 Synchronous Servomotors MSK ...
Page 260: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 258 279 Synchronous Servomotors MSK ...
Page 268: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 266 279 Synchronous Servomotors MSK ...
Page 274: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 272 279 Synchronous Servomotors MSK ...
Page 276: ...Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 274 279 Synchronous Servomotors MSK ...
Page 280: ...Notes Bosch Rexroth AG DOK MOTOR MSK PR12 EN P 278 279 Synchronous Servomotors MSK ...
Page 281: ...Notes DOK MOTOR MSK PR12 EN P Bosch Rexroth AG 279 279 Synchronous Servomotors MSK ...