MIC612 Thermal Camera
On-Screen Display (OSD) Menus (Bosch Protocol) | en
47
Bosch Security Systems, Inc.
Installation Manual
F.01U.249.416 | 2.0 | 2012.09
On models with the 35 mm thermal lens, you can also select either High Temp Thermal Meter
or Low Temp Thermal Meter, to trigger an alarm on the OSD if the thermal spot meter
identifies that the temperature of an object in the view of the camera is outside of the
temperature threshold set in the system. By default, the option is "Not Set." For more details,
see
Section 8.4 Triggering Alarms On Detection of Objects Outside of Set Thermal Temperature
Threshold, page 58
.
Outputs Setup Submenu
Outputs Setup Submenu Choices:
Outputs Setup
Defines physical outputs and keyboard commands for use in a rule.
Outputs 1-4
Defines a physical output: N.O. (Normally Open circuit) (default setting) or N.C. (Normally
closed circuit).
Outputs 5-12
Defines a command output for use in a rule.
Outputs Setup...
Exit...
1. NONE
2. NONE
3. NONE
4. NONE
5. NONE
6. NONE
7. NONE
8. NONE
9. NONE
10. NONE
11. NONE
12. NONE
Focus / Iris: Select Type
Right / Left: Select Mode
Option
Description
NONE
(Default setting) No command defined.
Aux On
Responds to a keyboard
ON
command.
Aux Off
Responds to a keyboard
OFF
command.
Shot
Responds to a Preset shot.
OSD
Displays the output on the on-screen display.
Transmit Transmits a message back to the head end (available with RS-232 serial and Bilinx
connections).